摘要
在架空输电线路总损耗的基础上,用数学极值方法推导出了考虑电压变化影响时架空输电线路经济负荷功率的计算公式,并得出当架空输电线路按经济功率Sj=((G/R)~(1/2))U2运行时,其输电效率最高ηmax=1-2((GR)~(1/2))/cosφ,线路的损耗最小的结论。
On the basic of total consumption of overhead electric power transmission line, using mathematical method of extremum, a computational formula considered the impact of voltage changing of overhead transmission line economic load power was deduced.And a conclusion is drawn that when overhead transmission line operates according to the economic load power(Sf=√G/R·U^2), its power transmission cfficiency is the highest(ηmax=1-2√GR/cosφ) and the line loss is the minimum.
出处
《大众科技》
2012年第10期101-102,共2页
Popular Science & Technology
基金
省级科研项目(08LX287)
关键词
输电线路
输电效率
线路经济负荷功率
最小线路损耗
Electric power transmission line
Power transmission efficiency
Line economic load power
Minimum line loss