摘要 根据格型自适应的结构原理,运用了一种频率响应非对称的修正自适应格型陷波器(improved adaptive lattice notchfilter,I-ALNF)在科氏流量计上的应用,并把零极点参数全部引入自适应算法中,使得算法与陷波器完全匹配,且使陷波器具有更好的特性。仿真结果表明,修正格型自适应陷波器比格型自适应陷波器的频率跟踪精度更高,稳定性更好。 According to the lattice ada tion adaptive lattice notch filter ( improved ptive structure principle, using a frequency response asymmetry correc- adaptive lattice notch filter, I-ALNF) in the application of Coriolis mass flowmeter, and the zero pole parameters of all of the adaptive algorithm, so the algorithm and the notch filter match exactly, and the notch filter have better characteristics. The simulation results show that, modified lattice adaptive notch filter in adaptive notch filter frequency tracking accuracy is high, the stability is better.
作者 乌伟
机构地区 西京学院
出处 《科学技术与工程》 北大核心 2012年第30期8103-8105,8115,共4页 Science Technology and Engineering
基金 陕西省自然科学基础研究计划项目(SJ08A26) 中小企业技术创新基金(08C26226102372)资助
关键词 科氏流量计 修正 格型自适应陷波器 跟踪精度 coriolis flowmeter ,correction ,adaptive IIR notch filter ,tracking accuracy
  • 相关文献

参考文献6

二级参考文献26

  • 1徐科军,倪伟,陈智渊.基于时变信号模型和格型陷波器的科氏流量计信号处理方法[J].仪器仪表学报,2006,27(6):596-601. 被引量:34
  • 2张海涛,涂亚庆.计及负频率影响的科里奥利质量流量计信号处理方法[J].仪器仪表学报,2007,28(3):539-544. 被引量:40
  • 3TU Y Q, ZHANG H T. Method for CMF signal processing based on the recursive DTFF algorithm with negative frequency contribution[J]. IEEE Transactions On Instrumentation And Measurement, 2008, 57(11):2647-2653.
  • 4DERBY H V, BOSE T, RAJAN S. Method and apparatus for adaptive line enhancement in coriolis mass flow meter measurement [P].US Patent No.5555190, Sep. 10, 1996.
  • 5JACOBSEN E, LYONS R. The sliding DFF[J]. Ieee Signal Processing Magazine, vol. 20, pp. 74-80, Mar 2003.
  • 6JACOBSEN E, LYONS R. An update to the sliding DFT ieee signal processing magazine, 2004.
  • 7Texas Instruments. TMS320F28335, TMS320F28334, TMS320F28332, TMS320F28235, Digital Signal Controllers (DSCs) Data Manual. February, 2008.
  • 8倪伟.[D].合肥工业大学自动化研究所,1999.
  • 9Yoshimura Hiroyuki. Phase difference measuring apparatus and flowmeter thereof. European Patent Application, EP 0702212A2,20.03. 1996.
  • 10H.V. Derby, T. Bose. S. Rajan. Method and apparatus for adaptive line enhancement in Coriolis mass flow meter measurement. US Patent No. 5555190, Sep. 10,1996.

共引文献55

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部