期刊文献+

正方形管内顺序放置扰流线圈后的传热行为(英文)

Heat Transfer Behavior in a Square Duct with Tandem Wire Coil Element Insert
下载PDF
导出
摘要 Effects of insertion of tandem wire coil elements used as turbulator on heat transfer and turbulent flow friction characteristics in a uniform heat-flux square duct are experimentally investigated in this work. The experiment is conducted for turbulent flow with the Reynolds number from 4000 to 25000. The wire coil element is inserted into the duct with a view to generating a swirl flow that assists to wash up the flow trapped in the duct corners and then increase the heat transfer rate of the test duct. Apart from the full-length coil, 1D and 2D length coil elements placed in tandem inside the duct with various free-space lengths are introduced to reduce the friction loss. The results obtained from these wire coil element inserts are also compared with those from the smooth duct. The experimental results reveal that the use of wire coil inserts for the full-length coil, 1D and 2D coil elements with a short free-space length leads to a considerable increase in heat transfer and friction loss over the smooth duct with no insert. The full-length wire coil provides higher heat transfer and friction factor than the tandem wire coil elements under the same operating conditions. Also, performance evaluation criteria to assess the real benefits in using the wire coil insert into the square duct are determined. Effects of insertion of tandem wire coil elements used as turbulator on heat transfer and turbulent flow friction characteristics in a uniform heat-flux square duct are experimentally investigated in this work. The experiment is conducted for turbulent flow with the Reynolds number from 4000 to 25000. The wire coil element is inserted into the duct with a view to generating a swirl flow that assists to wash up the flow trapped in the duct corners and then increase the heat transfer rate of the test duct. Apart from the full-length coil, 1D and 2D length coil elements placed in tandem inside the duct with various free-space lengths are introduced to reduce the friction loss. The results obtained from these wire coil element inserts are also compared with those from the smooth duct. The experimental results reveal that the use of wire coil inserts for the full-length coil, 1D and 2D coil elements with a short free-space length leads to a considerable increase in heat transfer and friction loss over the smooth duct with no insert. The full-length wire coil provides higher heat transfer and friction factor than the tandem wire coil elements under the same operating conditions. Also, performance evaluation criteria to assess the real benefits in using the wire coil insert into the square duct are determined.
出处 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第5期863-869,共7页 中国化学工程学报(英文版)
关键词 串联线圈 传热行为 元素 风管 方形 湍流传热 自由空间 摩擦损失 heat transfer, wire coil insert, square duct, turbulator
  • 相关文献

参考文献21

  • 1Shoji, Y, Sato, K, Oliver, D.R, Heat transfer enhancement in round tube using coiled wire: Influence of length and segmentation, Heat Transfer-Asian Res, 32 (2), 99-107 (2003).
  • 2Garcia, A, Vicente, EG, Viedma, A, Experimental study of heat transfer enhancement with wire coil inserts in laminar-transition- turbulent regimes at different Prandtl numbers, Int. J. Heat Mass Transfer, 48, 4640-4651 (2005).
  • 3Uttarwar, S.B, Rao, M.R, Augmentation of laminar flow heat transfer in tubes by means of coiled wire inserts, Trans. ASME, 107, 930-935 (1985).
  • 4Chiou, J.P, Experimental investigation of the augmentation of forced convection heat transfer in a circular tube using spiral springinserts, Trans. ASME, 109, 300 307 (1987).
  • 5Prasad, R.C, Shen, J, Performance evaluation using exergy analy- sis-Application to wire-coil inserts in forced convection heat transfer, lnt. J. Heat Mass Transfer, 37 (15), 2297-2303 (1994).
  • 6Ravigururajan, T.S, Bergles, A.E, Development and verification of general correlations for pressure drop and heat transfer in sin- gle-phase turbulent flow in enhanced tubes, Exp. Therm. Fluid Sci, 13, 55 70 (1996).
  • 7Wang, L, Sunden, B, Performance comparison of some tube in- serts, Int. Comm. Heat Mass Transfer, 29 (1), 45-56 (2002).
  • 8Yakut, K, Sahin, B, The effects of vortex characteristics on per- formance of coiled wire turbulators used for heat transfer augmenta- tion, AppL Therm. Eng, 24 (16), 2427-2438 (2004).
  • 9Ozceyhan, V, Conjugate heat transfer and thermal stress analysis of wire coil inserted tubes that are heated externally with uniform heat flux, Energy Convers. Manage, 46, 1543-1559 (2005).
  • 10Naphon, P, Effect of coil-wire insert on heat transfer enhancement and pressure drop of the horizontal concentric tubes, lnt. Comm. Heat Mass Transfer, 33 (6), 753-763 (2006).

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部