摘要 The investigation of a novel thermal neutron detector is developed to fulfill the requirements of the high intensity power diffractometer (HIPD) at the Chinese Spallation Neutron Source (CSNS). It consists of two layers of 6LiF/ZnS(Ag) scintillators, two layers of crossed WLSF arrays, several multi-anode photo multiplier tubes (MA-PMT), and the matching readout electronics. The neutron detection efficiency of the scintilltors, the light transportation ability of the WLSF, and the spatial linearity of the readout electronics are measured and discussed in this paper. It shows that the sandwich structure and the compact readout electronics could fulfill the needs of the HIPD. A prototype with a 10 cm×10 cm sensitive area has been constructed to further study the characteristics of the neutron scintillator detector. The investigation of a novel thermal neutron detector is developed to fulfill the requirements of the high intensity power diffractometer (HIPD) at the Chinese Spallation Neutron Source (CSNS). It consists of two layers of 6LiF/ZnS(Ag) scintillators, two layers of crossed WLSF arrays, several multi-anode photo multiplier tubes (MA-PMT), and the matching readout electronics. The neutron detection efficiency of the scintilltors, the light transportation ability of the WLSF, and the spatial linearity of the readout electronics are measured and discussed in this paper. It shows that the sandwich structure and the compact readout electronics could fulfill the needs of the HIPD. A prototype with a 10 cm×10 cm sensitive area has been constructed to further study the characteristics of the neutron scintillator detector.
出处 《Chinese Physics C》 SCIE CAS CSCD 2012年第11期1089-1094,共6页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China(11175257) Key Laboratory of Neutron Detection and Electronics of Dongguan Municipality
关键词 6LiF/ZnS(Ag) scintillator neutron detector wavelength shifting fiber detection efficiency 6LiF/ZnS(Ag) scintillator neutron detector wavelength shifting fiber detection efficiency
  • 相关文献

参考文献12

  • 1Yamada Y, Watanabe N, Niimura Net al. Physica B, 1998, 42:241.
  • 2WEI Jie. Mordern Physics, 2007, 06:22 (in Chinese).
  • 3Alex C. Nucl, Instrum. Methods A, 2005, 551:88.
  • 4Rhodes N J, Wardle A G, Boram A J et al. Nucl. Instrum. Methods A, 1997, 392:315.
  • 5Crow M L, Hodges J P, Cooper R G. Nucl. Instrum. Meth- ods A, 2004, 529:287.
  • 6HE Lun-Hua. CSNS High Intensity Powder Diffractometer. In: CSNS International Advisory Committee Review Meeting Bieijing, China 2011. 923.
  • 7http://www.eljentechnology.com/index.php/joomla- overview/neutron-detectors/113-ej -426.
  • 8http://www.detectors.saint-gobain.com/.../Organics- Brochure.pdf.
  • 9Kojima T, Katagiri M, Tsutsui Net al. Nucl. Instrum Methods A, 2004, 529:325.
  • 10http://www.detectors.saint-gobain.com/fibers.aspx.