摘要 对庭院模式化保温猪舍进行了 4年中间试验。结果表明 :围护结构和猪床采用保温隔热设计满足了使用要求 ,冬季窝内温暖干燥 ,气温和气湿分别为 9 84℃和 70 9% ,夏季舍内外温差 3℃以内。育肥猪全年平均日增重约为 6 43 6 5g。通风换气系统性能可靠 ,有效地排除水汽和有害气体 ,氨、硫化氢和二氧化碳的体积分数各为 6 9cm3 /m3 、5 34cm3 /m3 和 0 0 0 31m3 /m3 。猪舍布局合理 。 An extensive experiment on standard yard heat preserving pigsty has been carried out for four years The results showed that the surrounding constructure and bed of room met the requirements of heat preservation design The temperature and relatie humidity in the pens kept at 9 84 ℃ and 0 9% respectively The pens were warm and dry during winter However,there was a 3 ℃ difference in temperature between in and out of the house Performance of pigs was improved,the overall average daily gain for one year was about 643 65 g Ventilation system was valid,the air contents of NH 3,H 2S and CO 2 in the house was 6 9 cm 3/m 3,5 34 cm 3/m 3 and 0 003 1 m 3/m 3 respectively The pig house was arranged for convenient rational management
出处 《河北职业技术师范学院学报》 2000年第1期30-32,共3页 Journal of Hebei Vocation-Technical Teachers College