期刊文献+

光棒、标准喉罩和普通喉镜在全身麻醉中应用的比较 被引量:2

A comparison of application of the Light wand, Laryngeal Mask Airway and direct laryngoscope during general anesthesia
下载PDF
导出
摘要 目的将光棒、标准喉罩和普通喉镜应用于全麻患者,并对其临床效果及安全性进行比较和评价。方法120例ASAI~Ⅱ级,拟行全身麻醉患者,随机分为光棒组(A组,n=40)、喉罩组(B组,n=40)和喉镜组(C组,n=40),于常规静脉麻醉诱导后分别进行光棒引导气管插管,标准喉罩置人,普通喉镜气管插管。观察记录诱导前,诱导后,插管(喉罩)后1、3、5min时患者血压和心率,以及3组插管时间、插管成功率及插管后并发症。结果3组插管成功率之间差异无统计学意义(P〉0.05)。A组插管时间明显低于其他2组(P〈0.05);B组和C组之间差异元统计学意义(P〉0.05)。C组对患者血流动力学影响明显高于其他2组(p〈0.05)。不良反应方面:C组术后咽喉疼痛的发生高于A组和B组(P〈0.05),A组和B组之间差异无统计学意义(P〉0.05)。结论光棒插管技术操作简便实用,容易掌握,并发症少,成功率高,是麻醉医师进行全身麻醉操作的较理想选择。 Objective To compare and evaluate the efficacy and safety during general anesthesia with Light wand, Laryngeal Mask Airway and the direct laryngoscope. Methods 120 patients, ASA I - II , undergoing elective surgery under general anesthesia were randomly allocated to one of the three groups : Laryngeal Mask Airway group ( group A, n =40) , Light wand group (group B, n =40) and the direct laryngoscope group ( group C, n =40). A standardized an- esthetic technique was used. The patients were inserted orally using each equipment after induction of general anesthesia. Heart rate and blood pressure were recorded before induction, after induction but before insertion, and at 1 min, 3 min, and5 min after insertion. The insertion time, the success rate of insertion at first attempt, the injuries and the incidence of airway complications of all groups were also observed. Results There were no statistical differences found in the success rate of insertion between all the three groups ( P 〉 0.05 ). The time of insertion of group A was significantly shorter than that of group C and group B ( P 〈0. 05 ). There were no statistical differences in time of insertion between group B and group C ( P 〉 0.05 ). The changes of hemodynamic parameters in group C was more significant than that in group A and group B ( P 〈 0.05 ). The injuries and the incidence of airway complications were also higher in group C than in group A and group B ( P 〈 0.05 ) , there were no statistical differences between group A and group B ( P 〉 0.05 ). Conclusions Compared with the direct laryngoscope and Laryngeal Mask Airway, general anesthesia using Light wand is more successful, safer, valid and less injurious.
作者 焦皓 齐敦益
出处 《徐州医学院学报》 CAS 2012年第8期553-556,共4页 Acta Academiae Medicinae Xuzhou
关键词 喉罩 光棒 喉镜 气管插管 全身麻醉 Light wand Laryngeal Mask Airway direct laryngoscope endotracheal intubation general anesthesia
  • 相关文献

参考文献11

  • 1应诗达.气管内,支气管内插管[M]//庄心良,曾因明,陈伯銮.现代麻醉学.3版.北京:人民卫生出版社,2003:872-935.
  • 2Takahashi S, Mizutani T, Miyabe M, et al. Hemodynamic respon- ses to tracheal intubation with laryngoscope versus light wand intu-bating device (Trachlight) in adults with normal airway [ J ] . Anesth Analg, 2002,95 (2) :480 - 484.
  • 3Durrani M, Barwise JA, Johnson RF, et al. Intravenous chloro- procaine attenuates hemodynamic changes associated with direct la- ryngoscopy and tracheal intubation [ J ]. Anesth Analg, 2000,90 (5) : 1208 - 1212.
  • 4Takita K, Morimoto Y, Kemrnotsu O. Tracheal lidocaine attenu- ates the cardiovascular response to endotracheal intubation [ J ]. Can J Anaesth, 2001,48(8) :732 -736.
  • 5Choyce A, Avidan MS, Harvey A, et al. The cardiovascular re- sponse to insertion of the intubating laryngeal mask airway [ J ]. Anaesthesia, 2002,57 (4) :330 - 333.
  • 6王伟芝,张彩云,庞军涛.喉罩与气管内插管在乳腺切除术病人全麻中的应用[J].江苏医药,2007,33(9):945-946. 被引量:2
  • 7Liao X, Yang QY, Xue FS, et al. Bolus dose remifentanil and sufentanil blunting cardiovascular intubation responses in chil- dren : a randomized, double - blind comparison [ J ]. Eur J Anaes- thesiol, 2009,26( 1 ) :73 - 80.
  • 8Cheng EY. Assessment and management of the difficult airway in the critically HI adult [ J]. Contemporary Critical Care, 2005,3 (4) :1 - 12.
  • 9Hamaya Y, Dohi S. Differences in cadiovascular response to air- way stimulation at different sites and blockade of the responses by lidoeaine [ J]. Anesthesiology, 2000,93 ( 1 ) :95 - 103.
  • 10Friedman PG, Rosenberg MK, Lebenbom Mansoor M, et al. A comparison of light wand and suspension laryngoscopic intubation techniques in outpatients [J]. Anesth Analg, 1997,85 ( 3 ) : 578 - 582.

二级参考文献11

  • 1Cheng EY. Assessment and management of the difficult airway in the critically Ⅲ adult[J]. Contemporary Critical Care.2005.3(4) : 1 - 12.
  • 2(Theng KI, Chu KS, Chau SW, et al. Lightwand assisted intubation of patients in the lateral decubitus position[J].Anesth Analg , 2004.99 : 279 - 283.
  • 3Naguib M. Scamman FL, Sullivan C, et al. Predictive performance of three multivariate difficult tracheal intuhation models: a double blind, case-controlled study [J].Anesth Analg.2006.102:818 - 824.
  • 4Chen TH, Tsai SK, l.in CJ, et al. Does the suggested lightwand bent length fit every patient[J]. Anesthesiology, 20113,98(5):1070-1 076.
  • 5Takahashi S, Mizutani T, Miyabe M. et al. Hemodynamic responses to tracheal intubation with laryngoscope versus Iightwand intubating device (trachlight) in adults with normal airway[J].Anesth Anulg,2002,95 :480 - 484.
  • 6Simth CE, Sidhu TS, Lever J, et al. The complexity of tracheal intubation using rigid fiberoptic laryngoscopy (WuScope)[J].Anesth Analg ,1999,89:236 - 239.
  • 7Oczenski W.Ktenn H, Dahaba AA,et al. Hemodynamie and catecholamine stress responses to insertion of the combitube, laryngeal msak airway or tracheal inlubation [J]. Anesth Analg,1999,88:1 389 -1 394.
  • 8Turkstra TP. Craen RA, Pelz DM. et al. Cervial spine motion: a fluoroscopic comparison during intuhation with lighted stylet, GlideScope, and Macintosh laryngoscope [J].Anesth Analg ,2005.101:910-915.
  • 9张镜如 乔健天.生理学[M](第4版)[M].北京:人民卫生出版社,1995.403-404.
  • 10Nandwani N,Fairfield MC,Thompson J.The effect of laryngeal mask airway insertion on the position of the internal jugular vein[J].Anaesthesia,1997,52(2):77-79.

共引文献22

同被引文献25

  • 1王冬青,周永连,张雷波,宫炼.光棒气管插管折弯方法的研究[J].临床麻醉学杂志,2006,22(1):32-33. 被引量:53
  • 2周永连,王冬青,沈卫红.光索引导与喉镜直视气管插管对咽喉损伤的比较[J].临床麻醉学杂志,2006,22(5):387-387. 被引量:23
  • 3隋静湖,邓晓明,魏灵欣,刘建华,杨冬,罗茂萍,胥琨琳.颈前透光法用于Bonfils纤维光导硬镜引导全麻患者气管插管的可行性[J].中华麻醉学杂志,2007,27(9):860-861. 被引量:31
  • 4Harvey K, Davies R, Evans A, et al. A comparison of the use of Trachlight and Eschmann multiple-use introducer in simulated diffi- cult intubation [ J ]. Eur J Anaesthesiol, 2007,24 ( 1 ) :76 - 81.
  • 5Naguib M, Scamman FL, O'Sullivan C, et al. Predictive, performance of three multivariate difficult tracheal intubation models:a double- blind, case-controlled study [ J ]. Anesth Analg, 2006,102 ( 3 ) : 818 - 824.
  • 6Chen TH,Tsai SK,Lin CJ,et al. Does the suggested lightwand bent length fit every patient.'? The relation between bent length and pa- tient's thyroid prominence -to- mandibular angle distance[ J]. An- esthesiology ,2003,98 ( 5 ) : 1070 - 1076.
  • 7Takahashi S, Mizutani T, Miyabe M, et al. Hemodynamic responses to tracheal intubation with laryngoscope versus lightwand intubating de- vice(Trachlight) in adults with normal airway[ J]. Anesth Analg, 2002,95 (2) :480 - 484.
  • 8Morgan GE Jr,Mikhail MS,Murray MJ.摩根临床麻醉学[M].岳云,吴新民,罗爱伦,主译.北京:人民卫生出版社.2007:96.
  • 9Agro F, Barzoi G, Montecchia F. Tracheal intubation using a Macin- tosh Laryngoscope or a Glidescope in 15 patients with cervial spine immobilization [ J ]. Br J Anaesth, 2003,90 ( 5 ) :705 - 706.
  • 10Nishikawa K, Omote K, Kawana S, et al. A comparison of hemody- namic changes after endotracheal intubation by using the lightwand device and the laryngoscope in normotensive and hypertensive pa- tients [ J ]. Anesth Analg, 2000,90 ( 5 ) : 1023 - 1027.

引证文献2