摘要 水泥工业中,对旋转、重载主机设备电机启动方式的选择非常重要,而采用降压启动方式是合理的。在介绍电动机启动的基本要求和降压启动的必要性的基础上,详细介绍常用几种电动机降压启动方法的配置和启动特点。最后,以沙特YANBU日产10000t水泥熟料生产线为例,介绍了其各种水泥装备的电动机配置和相应的启动方式。 It is very important to choose starting method for the electromotor of rotating and overloading equipment in cement industry, and it is resonable to choose reduced-voltage starting method. Basic requirements of electromotor start-up and the necessity of re- duced-voltage start-up were introduced, and on that base,several reduced-voltage start-up metods and the configuration and characteristic were introduced in detail. Finally, the electromotor configuration and start-up method of all kinds of cement equipment in Saudi Arabia Yanbu 10 000 t/d clinker production line were introduced.