摘要
针对传统的基地式气动调节方式存在的高、低压加热器水位失控,加热器满水位或无水位运行及加热器水位波动大等问题,将汽液两相流自调节水位控制装置应用在125 MW汽轮发电机组高、低加热器疏水改造系统上,保证了加热器的水位稳定性,提高了机组的安全性,节约了燃煤和维护费用。
Aiming at the problems existed in traditional basis pneumatic regulating mode such as the water level of high/low pressure heater becoming out of control, operation of heater with full water level or no water level, water - level fluctuation of heater and so on, tile application of vapor - liquid two - phase flow automatic - regulation water level control device in upgrading high/low heater hydrophobic modifica- tion system of 125 MW turboset has guaranteed the stability of water level of heater, enhanced the safety of the turboset and saved the fire coal and costs of maintenance.
出处
《工业仪表与自动化装置》
2012年第5期92-94,共3页
Industrial Instrumentation & Automation
关键词
汽液两相流
加热器
疏水控制
应用
vapor- liquid two- phase tlow
heater
water drain control
application