摘要
双电动机离心机中主电动机处于电动机状态,副电动机处于发电动机状态。采用共直流母线可以很好地解决双电动机离心机中的能量反馈问题,本文以三菱A700变频器为例进行说明。
In the double-motor-centrifuge, the main motor runs in the motor state, while the vice motor is in the dynamotor state. Common DC bus can be a good solution to the problem of energy feedback in the centrifuge. This paper bases on Mitsubishi A700 inverter as an example to explain.
出处
《自动化博览》
2012年第10期66-66,69,共2页
Automation Panorama1
关键词
变频器
离心机
共直流母线
AC inverter
Centrifuge, Common DC bus