摘要
通过对天津原龙化工公司碱蒸发设备中的终浓缩反应器熔盐渗漏的返修,提出两套方案,实践证明其中后一种更为可行。这套新型实用的熔盐渗漏返修的方法和返修工艺,可为类似的加热器设备的制造提供一定的借鉴。
Through analysis of the final concentration heater's molten salt leakage in Tianjin Yuanlong Chemical company, two sets of repairing projects were put forward, it's proved that the second project is more feasible. The new technologic means to repair molten salt leakage can provide some references for manufacturing similar heater in future.
出处
《当代化工》
CAS
2012年第10期1143-1144,共2页
Contemporary Chemical Industry
关键词
终浓缩加热器
熔盐渗漏
双管板换热器
返修
Final concentration heater
Molten salt leakage: Double tube plate heat exchanger
Repair