摘要 目的探讨冠状动脉慢血流现象的影响因素。方法行冠状动脉造影检查提示冠状动脉无明显狭窄患者340例,根据校正TIMI血流计帧法分为冠状动脉慢血流组240例和血流正常组100例。结果单因素分析显示冠状动脉慢血流组男性、吸烟率、体质量指数、红细胞压积、血清肌酐、尿酸和三酰甘油水平高于血流正常组,年龄和高密度脂蛋白胆固醇水平低于血流正常组(P<0.05);多因素Logistic回归分析显示,吸烟(OR=1.863,95%CI:1.069~3.245,P<0.05)和红细胞压积(OR=1.169,95%CI:1.083~1.261,P<0.01)是冠状动脉慢血流的独立危险因素。结论吸烟和红细胞压积增高可促进冠状动脉慢血流现象的发生。 Objective To analyze the influence factors on coronary slow flow phenomenon (CSFP). Methods A total of 340 cases diagnosed by coronary angiography were divided into the CSFP group (n=240) and the normal coronary flow group (n= 100) according to the corrected TIMI frame count (CTFC). Results Single factor analysis showed that CSFP group had higher proportions of male, smoking ratio, body mass index, hematocrit level, serum creatinine level, serum uric acid level and triacylglycerol level, and had lower age and high density lipoprotein-cholesterol level in comparison with normal coronary flow group (P^0.05). Multivariate logistic regression analysis showed that smoking ratio (OR:I. 863, 95%CI..1. 069 to 3. 245,P〈0. 05) and hematocrit (OR: 1. 169, 95%CI: 1. 083 to 1: 261,P〈0.05) were the independent risk factors of the CSFP. Conclusion Smoking and high level of hematocrit might be involved in the pathogenesis of CSFP.
出处 《中华实用诊断与治疗杂志》 2012年第11期1048-1050,共3页 Journal of Chinese Practical Diagnosis and Therapy
基金 国家自然科学基金(81000130) 北京市2012年度基础临床合作研究基金(12JL58) 首都临床特色应用研究(Z121107001012068)
关键词 冠状动脉 慢血流现象 校正的TIMI血流计帧法 危险因素 Coronary artery slow flow phenomenon corrected TIMI frame count risk factors
  • 相关文献

参考文献11

二级参考文献59

  • 1王荔.重度吸烟冠心病患者的精神心理表现[J].中国临床康复,2004,8(18):3545-3545. 被引量:5
  • 2Mangieri E,Macchiarelli G,Ciavolella M,et al.Slow coronary flow:clinical and histopathological features in patients with otherwise normal epicardial coronary arteries[J].Cathet Cardiovasc Diagn,1996,37 (4):375-381.
  • 3Goel PK,Gupta SK,Agarwal A,et al.Slow coronary flow:a distinct angiographic subgroup in syndrome X[J].Angiology,2001,52 (8):507-514.
  • 4Gibson CM,Cannon CP,Daley WL,et al.TIMI frame count:a quantitative method of assessing coronary artery flow[J].Circulation,1996,93 (5):879-888.
  • 5Celik T,Iyisoy A,Kursaklioglu H,et al.ST elevation during treadmill exercise test in a young patient with slow coronary flow:a case report and review of literature[J].Int J Cardiol,2006,112 (2):e1-e4.
  • 6Yetkin E,Turhan H,Erbay AR,et al.Increased thrombolysis in myocardial infarction frame count in patients with myocardial infarction and normal coronary arteriogram:a possible link between slow coronary flow and myocardial infarction[J].Atherosclerosis,2005,181 (1):193-199.
  • 7Tambe AA,Demany MA,Zimmerman HA,et al.Angina pectoris and slow flow velocity of dye in coronary arteries--a new angiographic finding[J].Am Heart J,1972,84 (1):66-71.
  • 8Beltrame JF,Limaye SB,Wuttke RD,et al.Coronary hemodynamic and metabolic studies of the coronary slow flow phenomenon[J].Am Heart J,2003,146 (1):84-90.
  • 9Erdogan D,Caliskan M,Gullu H,et al.Coronary flow reserve is impaired in patients with slow coronary flow[J].Atherosclerosis,2007,191 (1):168-174.
  • 10Camsari A,Ozcan T,Ozer C,et al.Carotid artery intima-media thickness correlates with intravascular ultrasound parameters in patients with slow coronary flow[J].Atherosclerosis,2008,200 (2):310-314.