期刊文献+

管壳式换热器管子与管板胀接接头的可靠性分析

Analysis of Reliability of the Expansion Joint between the Tube and the Tube Sheet of the Tube-and-shell Heat Exchanger
下载PDF
导出
摘要 为提高管壳式换热器管子的管端与管板胀接接头的可靠性,分析了胀管过程的受力情况,认为GB151-89规定的胀管间隙和孔带尺寸偏大,实际应用中应加以注意,并提出胀接前最佳间隙C的计算公式。 In order to improve the reliability of the expansion joint between the tube end and the tube sheet of the tube-and-shell heat exchanger,the author analyzes the stress in the course of tube expansion, thinks that the clearance between expansible tubes and the distance between holes,stipulated by GB151 - 89,are a bit too large and should be noted in practical application, and proposes a calculation formula for C-the optimum clearance before expansion jointing.
作者 李永华
出处 《硫磷设计与粉体工程》 2000年第4期6-8,共3页 Sulphur Phosphorus & Bulk Materials Handling Related Engineering
关键词 换热器 管板胀接 可靠性分析 接头 管壳式 heat exchanger, tube sheet,expansion jointing,reliability,analysis
  • 相关文献

参考文献2

  • 1冯志良 冯素霞.关于列管换热器管子与管板胀接的几个问题[J].化工与通用机械,1983,(7):43-47.
  • 2陈永宁 黄日侯.换热器胀接接头质量控制的探讨[J].石油化工设备,1986,8:17-24.