期刊文献+

Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study 被引量:1

Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study
下载PDF
导出
摘要 The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第5期342-349,共8页 药物分析学报(英文版)
关键词 High performance liquid chromatography Mass spectrometry RASAGILINE Liquid-liquid extraction High performance liquid chromatography Mass spectrometry Rasagiline Liquid-liquid extraction
  • 相关文献

参考文献12

  • 1O. Weinreb, T. Amit, O. Bar-Am, et al., Rasagiline: a novel antiparkinsonian monoamine oxidase-b inhibitor with neuroprotective activity, Prog. Neurobiol. 92 (3) (2010) 330-344.
  • 2J. Leegwater-Kim, E. Bortan, The role of rasagiline in the treatment of Parkinson's disease, Clin. lnterv. Aging 5 (2010) 149-156.
  • 3M.F. Lew, R.A. Hauser, H.I. Hurtig, et al., Long-term efficacy of rasagiline in early Parkinson's disease, Int. J. Neurosci. 20 (6) (2010) 404-408.
  • 4S. Won Hyuk, K.S. Suslick, S. Yoo-Hum, Therapeutic agents for Alzheimer's disease, Curr. Med. Chem.-Cent. Nerv. Syst. Agents 5 (2005) 259-269.
  • 5M. Fernandez, E. Barcia, S. Negro, Development and validation of a reverse phase liquid chromatography method for the quantification of rasagiline mesytate in biodegradable PLGA microspheres, J. Pharm. Biomed. Anal. 49 (5) (2009) 1185-1191.
  • 6D. Haberle, K. Magyar, E. Szoko, Determination of the norepinephrine level by high-performance liquid chromatography to assess the protective effect of MAO-B inhibitors against DSP-4 toxicity, J. Chromatogr. Sci. 40 (9) (2002) 495-499.
  • 7C. Binda, F. Hubalek, M. Li, et al., Binding of rasagiline-related inhibitors to human monoamine oxidases: a kinetic and crystallographic analysis, J. Med. Chem. 48 (26) (2005) 8148-8154.
  • 8M. Song, L. Wang, H. Zhao, et al., Rapid and sensitive liquid chromatography-tandem mass spectrometry: assay development, validation and application to a human pharmacokinetic study, J. Chromatogr. B Analyt. Technol. Biomed. Life Sci. 875 (2) (2008) 515-521.
  • 9J. Ma, X. Chen, X. Duan, et al., Validated LC-MS/MS rnethod for quantitative determination of rasagiline in human plasma and its application to a pharmacokinetic study, J. Chromatogr. B Analyt. Technol. Biomed. Life Sci. 873 (2) (2008} 203 .208.
  • 10Guidance for Industry: Bioanalytical Method Validation, U.S. Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research (CDER), Center for Biologics Evaluation and Research (CBER), May 2001.

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;