期刊文献+

基于光流场模型的弹性配准在放射治疗中的应用 被引量:1

Elastic registration based on optical flow model and its application in clinical radiotherapy
下载PDF
导出
摘要 目的采用Matlab软件编程,实现基于光流场模型的图像弹性配准,并将其应用于放射治疗患者CT图像中,为进一步分析肿瘤及危机器官的变化提供软件支持。方法对接受放射治疗的宫颈癌患者的盆腔CT图像,分别基于Lucas-Kanade与Horn-Schunck光流场模型实施弹性配准。结果 Lucas-Kanade模型弹性配准前后对比,最小均方误差(MSE)减少59.80%(19.5915/32.7590),相关系数(CC)提高6.17%(0.0331/0.9369);Horn-Schunck模型弹性配准前后对比,最小MSE减少67.75%(22.1940/32.7590),CC提高6.36%(0.0596/0.9369)。结论上述两种基于光流场模型的弹性配准取得较好的配准效果,且耗时较少;但其精度对于细微差别仍显不足,需进一步提高形变的精确性。 Objective To achieve elastic registration based on optical flow model using Matlab software program, and ap ply it in radiotherapy CT image, in order to provide software support for further analysis of the tumor and the crisis in or gan changes. Methods Based on the Lucas-Kanade and Horn-Schunck optical flow model, elastic registration was imple mented on pelvic CT images of patient with cervical cancer. Results Compared with images before elastic registration, mean square error (MSE) decreased by 59.80% (19. 5915/32. 7590) after elastic registration based on the Lucas-Kanade model, while correlation coefficient (CC) increased by 6.17% (0. 0331/0. 9369). For Horn-Schunck model, MSE de creased by 67.75% (22. 1940/32. 7590), and CC increased by 6.36%(0. 0596/0. 9369). Conclusion Both Lucas-Kanade and Horn-Schunck optical flow model can be used to obtain elastic registration costing less time, but lack of precision for appearing small differences, and their accuracy need to be further imoroved.
出处 《中国医学影像技术》 CSCD 北大核心 2012年第11期2090-2093,共4页 Chinese Journal of Medical Imaging Technology
关键词 弹性配准 光流场模型 体层摄影术 x线计算机 放射治疗 Elastic registration Optical flow model Tomography, X-ray computed Radiotherapy
  • 相关文献

参考文献13

  • 1(Jhan P, Dinniwell R, Haider MA, et al. Inter and intrafraction al tumor and organ movement in patients with cervical cancer un dergoing radiotherapy: A cinematic MRI point of interest study Int J Radiat ()neol Biol Phys, 2008,70 ( 5 ) : 1507-1515.
  • 2Jhingran A, Salehpour M, Sam bladder and rectal volumes during ation therapy after hysterectomy. 2012,82(1) :256-262. M, et al. Vaginal motion and pelvic intensity-modulated radi Int J Radiat ()neol Biol Phys,.
  • 3庞皓文,邱杰,全红,孙帅,杨波,管秋,张福泉.宫颈癌调强放疗中膀胱解剖结构变化及对其吸收剂量影响研究[J].中华放射肿瘤学杂志,2011,20(3):218-221. 被引量:28
  • 4Noel CE, Santanam I., Olsen JR, et al. An automated method for adaptive radiation therapy for prostate cancer patients using continuous fiducial-based tracking. Phys Med F, iol, 2010,55 ( 1 ) : 65 82.
  • 5Yang D, Chaudhari SR, Goddu SM, et al. Deformable registra tion of abdominal kilovohage treatment planning CT and tomo- therapy daily megavohage CT for treatment adaptation. Med Phys, 2009,36(2) :329 338.
  • 6Castadot P, Lee JA, Parraga A, et al. Comparison of 12 deform- able registration strategies in adaptive radiation therapy for thetreatment of head and neck tumors. Radiother Oncol, 2008, 89 (1):1-12.
  • 7Yan D, Jaffray DA. Wong JW. A model to accumulate fractiona- ted dose in a deforming organ, lnt J Radiat Oncol Biol Phys, 1999, ,t4(3) :665675.
  • 8Brock KK, Lee M, Eccles CL, et al. De[ormable registration and dose accumulation to investigate marginal liver cancer recur rences. Int J Radiat Oncol Biol Phys, 2008,72(1) :$538.
  • 9Crum WR, Hartkens "F, Hill DI.. Non rigid image registration: Theory and practice. Br J Radiol, 2004,77:S140-S153.
  • 10Yang D, l.i H, l.ow DA, et al. A fast inverse consistent de-formable image registration method based on symmetric optical flow computation. Phys Med Biol, 2008,53(21):6143-6165.

二级参考文献28

  • 1冯林,张名举,贺明峰,戚正君,滕弘飞.用分层互信息和薄板样条实现医学图像弹性自动配准[J].计算机辅助设计与图形学学报,2005,17(7):1492-1496. 被引量:16
  • 2Mell LK, Roeske JC, Mundt AJ. A survey of intensity modulated radiation therapy use in the United States. Cancer,2003,98:204- 211.
  • 3Roeske JC, Lujan A, Rotmensch J, et al. Intensity-modulated whole pelvic radiation therapy in patients with gynecologic malignancies. Int J Radiat Oncol Biol Phys ,2000 ,48 :1613-1621.
  • 4Mell LK, Tiryaki H, Ahn KH, et al. Dosimetric comparison of bone marrow-sparing intensity-modulated radiotherapy versus conventional techniques for treatment of cervical cancer. Int J Radiat Oncol Biol Phys,2008,71:1504-1510.
  • 5Chen MF, Tseng C J, Tseng CC, et al. Clinical outcome in post hysterectomy cervical cancer patients treated with concurrent cisplatin and intensity-modulated pelvic radiotherapy: comparison with conventional radiotherapy. Int J Radiat Oncol Biol Phys, 2007,67 : 1438-1444.
  • 6Chan P, Dinniwell R, Haider MA, et al. Inter-and intrafractional tumor and organ movement in patients with cervical cancer undergoing radiotherapy: a cinematic-MRI point-of-interest study. Int J Radiat Oncol Biol Phys ,2008,70 : 1507-1515.
  • 7van de Bunt L, van der Heide UA, Ketelaars M, et al. Conventional, eonformal and Intensity-modulated radiation therapy treatment planning of external beam radiotherapy for cervical cancer:the impact of tumor regression. Int J Radiat Oncol Biol Phys, 2006,64 : 189-196.
  • 8Jhingran A, Salehpour M, Sam M, et al. Vaginal motion and bladder and rectal volumes during pelvic intensity-modulated radiation therapy after hysterectomy. Int J Radiat Oncol Biol Phys, 2011, In Press.
  • 9Raaymakers BW, Lagendijk JJ, Overweg J, et al. Integrating a 1.5 TMRI scanner with a 6 MV accelerator:proof of concept. Phys Med Biol,2009,54:229-237.
  • 10Van den PA,Evert Jan D Pol,Viergever MA.Medical image matching-a review with classification.IEEE engineering in Medicine and Biology,1993,12 (1):26