期刊文献+

Comparison between Two Bioassays in Monitoring and Evaluation of Water Quality

Comparison between Two Bioassays in Monitoring and Evaluation of Water Quality
下载PDF
导出
摘要 [ Objective] The aim was to compare the application of two bioassays to monitoring and evaluation of water quality. [ Method ] By using two bioassays (micronucleus detecting technology based on Vicia faba root tip cells and the bioassay by luminous bacteria), we monitored and evaluated seven kinds of single solutions respectively added different pollutants ( Hg, Cd, As, Cr6 + , Pb, I_A8 and CODc,) and a mixed solution added those seven pollutants. Afterwards, we compared their results under the same pollutant and concentration, so as to study the two bioassays' sensitivity and sensitive concentration to the seven pollutants. [ Result] Under the same pollutant and concentration, micronucleus detecting tech- nology based on Vicia faba root tip cells had responses to Hg, Cd, As and Cr6+ , but there was no response to Pb, LAS and CODer. However, the bioassay by luminous bacteria had responses to most pollutants except Cr6+. Comparing the sensitive degree and concentration to each pollutant, they can complement each other. For these seven pollutants, the bioassay by luminous bacteria was better than micronucleus detecting technology based on Vicia faba root tip cells. Meanwhile, from the testing result of the mixed solution, the combined toxicity of several pollutants in lower con- cantrations was serious. At the same time, contrasted to normal chemical methods, bioassays were fast and effective. [ Conclusion] The research could provide theoretical references for the correlation study of bioassays. [ Objective] The aim was to compare the application of two bioassays to monitoring and evaluation of water quality. [ Method ] By using two bioassays (micronucleus detecting technology based on Vicia faba root tip cells and the bioassay by luminous bacteria), we monitored and evaluated seven kinds of single solutions respectively added different pollutants ( Hg, Cd, As, Cr6 + , Pb, I_A8 and CODc,) and a mixed solution added those seven pollutants. Afterwards, we compared their results under the same pollutant and concentration, so as to study the two bioassays' sensitivity and sensitive concentration to the seven pollutants. [ Result] Under the same pollutant and concentration, micronucleus detecting tech- nology based on Vicia faba root tip cells had responses to Hg, Cd, As and Cr6+ , but there was no response to Pb, LAS and CODer. However, the bioassay by luminous bacteria had responses to most pollutants except Cr6+. Comparing the sensitive degree and concentration to each pollutant, they can complement each other. For these seven pollutants, the bioassay by luminous bacteria was better than micronucleus detecting technology based on Vicia faba root tip cells. Meanwhile, from the testing result of the mixed solution, the combined toxicity of several pollutants in lower con- cantrations was serious. At the same time, contrasted to normal chemical methods, bioassays were fast and effective. [ Conclusion] The research could provide theoretical references for the correlation study of bioassays.
出处 《Meteorological and Environmental Research》 2012年第3期49-52,共4页 气象与环境研究(英文版)
基金 Supported by Scientific and Technological Planning Project of Tianjin City (05ZHGCNC01600) Special Scientific Research Fee of Central Public Welfare Institutes (2009-XYP-06)
关键词 BIOASSAY Water quality MONITORING Evaluation China Bioassay Water quality Monitoring Evaluation China
  • 相关文献

参考文献9

二级参考文献121

共引文献78

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部