阐述了采用5E—IRS3000自动红外测硫仪时应注意标样校正、自动机构、智能控制系统、干燥装置、气源等环节的异常问题,并从仪器的校正方面对仪器的精密度、准确度和稳定性进行验证,指出了测试过程中应注意的事项。
The abnormal problems in various units of standard sample correction, automatic gear, intelligent control system, drying equipment and air source in 5E-IRS3000 automatic infrared sulfur analyzer were described in this paper. The precision, accuracy and stability of the analyzer was tested in view of instrument correction, and some points for attention during the determination was presented.