摘要
介绍了常规的哈氏可磨性指数测定仪的使用流程,阐述了利用Excel进行校正图的快速绘制及计算哈氏可磨性指数的方法,并分析了新型哈氏可磨性指数测定仪的使用情况。
The use procedure of routine Hardgrove grindability index analyzer was introduced in this paper. The method of fast drawing of calibration chart and calculation of Hardgrove.grindability index by use of Excel was described. And the application status of new type of Hardgrove grindability index analyzer was analyzed.
出处
《煤质技术》
2012年第A01期37-38,共2页
Coal Quality Technology
关键词
哈氏可磨性指数测定仪
校正图
趋势线
自动校正
Hardgrove grindability index
analyzer
calibration chart
automatic correction