期刊文献+

除法式磁光盘信号检测方法的研究 被引量:2

Study of the Detection Method Using the Intensity Dividing Readout for the Magneto-optical Disks
原文传递
导出
摘要 研究了除法式磁光信号检测的原理和方法 ,分析表明 ,该检测方式不受激光功率的波动和盘片反射率变化的影响 ,提高了数据读出的准确性 .实验结果显示除法式检测方式比差动式磁光信号检测更适合静态实验的要求 . The intensity dividing readout (IDR) method for magneto optical disks is analytically discussed. Compared with the differential readout method, the IDR method can eliminate the influence of the fluctuation of the laser power and the reflectivity on the thin film. Experimental results show that it′s a useful measuring method for evaluating magneto optic media in the static test.
出处 《中国激光》 EI CAS CSCD 北大核心 2000年第8期737-740,共4页 Chinese Journal of Lasers
关键词 磁光盘 除法式检测 信号检测 MO detection, magneto optical disk, differential readout, intensity dividing readout
  • 相关文献

参考文献3

  • 1M. Mansuripur,G. A. N. Connell.Signal and noise in magneto-optical readout[].Japanese Journal of Applied Physics.1982
  • 2A. G. Dewey.Measurement and modeling of optical disk noise[].Proceedings of SPIE the International Society for Optical Engineering.1986
  • 3K. Egashira,T. Yamada.Kerr effect enhancement and improvement of readout characteristics in MnBi film memory[].Japanese Journal of Applied Physics.1974

同被引文献14

  • 1SHEN D F, MATSUSHITA P, SUKURAI Y. Effect of annealing on the compensation temperature of RE-TM amorphous films[J]. IEEE Trans Magn, 1981,MAG-17:2704-2706.
  • 2ROBINSON C C. Longitudinal Kerr magneto-optic effect in thin films of Iron, nickel, and permalloy[J].J Opt Soc Am, 1963, 53. 681-689.
  • 3MANSUIPUR M,CONNELL G A N. Signal and noise in magneto-optical readout[J]. J. Appl. Phys, 1982,53(6) :4485-4494.
  • 4EGASHIRA E, YAMADA T. Kerr-effect enhancement and improvement of readout characteristics in MnBi filmmemory [J]. J. Appl. Phys, 1974, 45 (8):3643-3648.
  • 5刘公强 刘湘林.磁光调制和法拉第旋转测量.光学学报,1984,4(7):588-591.
  • 6朱伟荣,董国胜,陈艳,金晓峰,钱世雄,陈良尧.一种测量薄膜磁性的表面磁光克尔效应装置[J].真空科学与技术,1997,17(4):243-246. 被引量:6
  • 7Z. Q. Qiu, S. D. Bader. Surface magneto-optic Kerr effect[J]. Review of Scientific Instruments, 2000, 71 (3) : 1243-1255.
  • 8G. Will, A. Ding, Y. B. Xu. Development of aninsi- tu magnetoelastic magneto-optical Kerr effect magne- tometer[J]. Review of Scientific Instruments,2012,83: 064707-1.
  • 9S. Polisetty, J. Scheffler, S. Sahoo, et al. Optimiza-tion of magneto-optical Kerr setup: Analyzing experi- mentalass emblies using Jones matrix formalism [J].Review of Scientific Instruments, 2010,79 : 055107-1.
  • 10T Kuschel, H Bardenhagen, H Wilkens, et al. Vecto- rial magnetornetry using magnetooptic Kerr effect inclu- ding firstand second-order contributions for thin ferro- magnetic films[J]. J. Phys. D: Appl. Phys. ,2011, 44:265003 : 1-14.

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部