摘要 本文论述用于测量细胞膜离子通道电流的放大器的电路方案 .因被测电流在 1pA到nA级的范围内 ,而输出电压要求达到计算机便于处理的数值 .故需采用多级放大电路 .被测电流属极微弱的信号 ,噪声问题是设计中的关键 .对于多级放大器来说 ,前置放大级 (探头电路 )的低噪声设计至关重要 .文中分析放大电路中的主要元、器件的背景噪声 ,用噪声电流和噪声电压的功率密度谱 (PDS)SI(f)和Sv(f)来表征其特性 .给出了所设计的PC Ⅱ型膜片钳放大器的主要性能参数和记录的电流波形 . The configuration of the amplifier for recording the ionic channel current of the cell is described here.The measured currents vary from 1 pA to nanoampers,and the output voltage is required to be processed by the computer.Therefore,the amplifier must be constructed in multistages.The key point for designing this amplifier is the low noise technique,especially for the headstage.The background noise of the main components and devices are particularly analyized with power density spectrum S I(f) and S v(f ) to characterize their characteristics.The test results of the designed patch clamp amplifier model PC Ⅱ satisfy the practical requirement and the experimental data are given.
出处 《电子学报》 EI CAS CSCD 北大核心 2000年第9期42-45,共4页 Acta Electronica Sinica
基金 国家教委博士点基金!(No.894871 5) 湖北省科委 1 992年重点科技研究项目基金!(No .92 1P0 50 1 )
关键词 膜片钳 放大器 低噪声设计 patch clamp current voltage converter background noise low noise design
  • 相关文献

参考文献3

二级参考文献4

共引文献6

同被引文献32

  • 1高刚强,瞿安连.膜片钳放大器瞬态电流伪差的自动补偿[J].华中科技大学学报(自然科学版),2004,32(10):63-65. 被引量:3
  • 2杨秀文,刘云山.玻璃介电常数(ε_r)的测定[J].河北大学学报(自然科学版),1995,15(2):82-85. 被引量:1
  • 3叶燚,胡刚,瞿安连.全自动膜片钳放大器快电容补偿技术改进[J].上海生物医学工程,2006,27(2):98-101. 被引量:2
  • 4戴逸松.电子系统噪声及低噪声设计方法[M].长春:吉林人民出版社,1985..
  • 5C. D. Motchenbacher F. C. Fitchen 龙忠琪译.Low noise Electronic design[M].John Wiley & Sons,Inc, 北京:国防工业出版社,1973,1997..
  • 6SIGWORTH F J. Design of the EPC-9, a computer-con- trolled patch-clamp amplifier. 1. Hardwar. [J]. J Neurosci Methods, 1995,56(2) : 195-202.
  • 7SIGWORTH F J, AFFOLTER H, NEHER E. Design of the EPC-9, a computer-controlled patch-clamp amplifier. 2. Soft- ware[J]. J NeurosciMethods, 1995,56(2): 203-215.
  • 8GII.LIS K D. Single-channel recording [M]. 2nd ed. New York: Plenum Press, 1995: 155-198.
  • 9ZHANG H, QU A, LUO J, et al. Error analysis of Cm measurement under the whole-cell patch-clamp recording [J].J Neurosci Methods, 2010, 185(2): 307-314.
  • 10CHEN P, GIlA.IS K D. The noise of membrane capacitance measurements in the whole-cell ecording configuration [J]. Biophys J, 2000, 79(4): 2162-2170.