期刊文献+

浸渍法测定PVC地板密度存在的问题及改进意见

The problems and suggestions for measuring the density of PVC floor by immersion method
下载PDF
导出
摘要 根据牛顿定律,从力学观点出发,对浸渍法测定PVC地板密度的准确性进行了分析,提出修改意见并通过实验进行验证。实验得出:试样尺寸较小时忽略金属丝的质量使测得的地板密度偏差较大;试件尺寸较大时,金属丝的质量可以忽略。采用修正公式可使实验更加严谨,数据准确。同时,修正公式在试样密度大于或小于浸渍液密度时都可适用,统一了密度测量的操作方法和计算公式。 According to Newton's law,the accuracy of determining PVC floor density by the method of immersion is analyzed from the viewpoint of mechanics,and modified suggestions was studied and verified through experiment.The results show that the density of sample in small size has large deviation when the quality of metal wire was ignored,while the quality of metal wire need not be taken into account when the sample was in larger size.The precise date can be obtained by adopting the formula,which can be the testing method of density without considering the difference of sample and steeping liquor in density.
出处 《中国建材科技》 2012年第5期1-3,共3页 China Building Materials Science & Technology
关键词 地板 密度 浸渍法 试样尺寸 floor density immersion method sample size
  • 相关文献

参考文献6

二级参考文献7

  • 1JJF1059—1999.测量不确定度评定与表示.[S].,..
  • 2JJG98—1990.非自动天平.[S].,..
  • 3GB 1033—86,塑料密度和相对密度试验方法.
  • 4ISO 1183 - 1987 Plastics Methods for Determining the Density and Relative Density of Non-Cellular Plastics.
  • 5上海市计量测试技术研究所.常用测量不确定度评定方法及应用实例.北京:中国计量出版社,2001.4.
  • 6ASTM D792 -00 Standard Test Method for Density and Specific Gravity (Relative Density) of Plastics by Displacement.
  • 7JJG 99—1990,砝码.

共引文献3