摘要 目的探讨建立离体猪肝机械灌注模型的可行性及在高强度聚焦超声(HIFU)基础研究中的意义。方法对屠宰场获取的2l例猪肝以双血管(经门静脉和肝动脉)、自体血灌注液、体外循环机离体灌注4 h,监测肝脏的颜色、质地、质量、血流动力学(流量及压力)、彩色多普勒超声影像、胆汁分泌量、组织病理学变化以评价灌注效果。结果 19例猪肝同时经门静脉和肝动脉插管成功,2例肝动脉插管失败。灌注后4 h肝脏质地柔软、血流动力学各参数稳定且保持在相对正常的生理范围内,灌注3 h内胆汁分泌量>3 ml/h,组织病理学显示脏组织总体无形态结构的改变。结论离体猪肝机械灌注模型是稳定、可行的,能满足HIFU基础研究中的实验要求。 Objective To explore the feasibility of establishing an isolated porcine liver machine perfusion model and assess its value in high-intensity focused ultrasound studies. Methods Twenty-one isolated porcine livers were perfused with autologous blood for 4 h through dual vessels (portal vein and hepatic artery) cannulation using an extracorporeal circulation machine under a subnormothermic perfusion condition. The perfusion model was assessed by monitoring the liver color, texture, liver weight gain, hemodynamic parameters, color Doppler flow imaging, bile output and histopathology. Results Nineteen isolated porcine livers were successfully cannulated with dual vessels, and failure of hepatic artery intubation occurred in two porcine livers. After machine perfusion for 4 h, the isolated livers maintained a soft texture with stable hemodynamic levels within relative normal physiological ranges. The bile output was more than 3 ml/h within the initial 3 h of perfusion. Histopathological examination demonstrated no morphological or structural changes of the liver tissues. Conclusion The isolated porcine liver per fusion model is stable and feasible, and can be used for high-intensity focused ultrasound studies.
出处 《南方医科大学学报》 CAS CSCD 北大核心 2012年第11期1564-1567,共4页 Journal of Southern Medical University
基金 国家重点基础研究发展计划项目(国家973计划)(2011CB707900)~~
关键词 离体猪肝 机械灌注 模型 高强度聚焦超声 isolated porcine liver machine perfusion model high-intensity focused ultrasound
  • 相关文献

参考文献18

  • 1Monbaliu D, Brassil J. Machine perfusion of the liver: past, present and fature[J]. Curr Opin Organ Transplant, 2010, 15(2): 160-6.
  • 2Vogel T, Brockmann JG, Friend PJ. Ex-vivo normothermic liver perfusion: an update[J]. Curr Opin Organ Transplant, 2010, 15(2): 167-72.
  • 3李发琪,龚小波,胡凯,李崇燕,徐杰,谭启华,王智彪.声通道上的肋骨对高强度聚焦超声在羊肝内形成凝固性坏死的影响[J].中华超声影像学杂志,2006,15(12):943-945. 被引量:5
  • 4Zhu H, Zhou K, Zhang L, et al. High intensity focused ultrasound (HIFU) therapy for local treatment of hepatocellular carcinoma: role of partial rib resection[J]. Eur J Radiol, 2009, 72(1): 160-6.
  • 5Couret LN, Miller NR, Rivens IH, et al. Experimental methodologies for studying the effects of perfusion on high intensity focused ultrasound(HIFU)[J]. Ultrasonics, IEEE Symposium, 2003, 1: 142-5.
  • 6Carraro A, Gringeri E, Calabrese F, et al. A new experimental model of isolated perfused pig liver to support acute hepatic failure [J]. Transplant Proc, 2007, 39(6): 2028-30.
  • 7沈中阳,陈新国.临床肝移植[M].北京:科学出版社,2010:41-5.
  • 8Nagel S, Hegemann O, Groneberg DA, et al. An improved model of isolated hemoperfused porcine livers using pneumatically driven pulsating blood pumps[J]. Toxicol Pathol, 2005, 33(4): 434-40.
  • 9Han HC, Fung YC. Species dependence of the zero-stress state of aorta: pig versus rat[J]. J Biomech Eng, 1991, 113(4): 446-51.
  • 10Butler A J, Rees MA, Wight DG, et al. Successful extracorporeal porcine liver perfusion for 72 hr[J]. Transplantation, 2002, 73(8): 1212-8.