期刊文献+

牙科金属在人工唾液中的耐腐蚀性 被引量:3

Corrosion Resistance of Dental Alloys in Artificial Saliva
下载PDF
导出
摘要 用电化学方法研究了纯钛、钴铬和镍铬合金在人工唾液中的耐腐蚀性,采用SPSS11.0软件对数据进行单因素方差分析。结果显示,1h的开路电位值为纯钛<镍铬<钴铬;自腐蚀电位为纯钛<镍铬<钴铬;腐蚀电流密度为镍铬>钴铬>纯钛;极化电阻为纯钛>钴铬>镍铬。三者的开路电位、自腐蚀电位和腐蚀电流密度均具有统计学差异;纯钛与镍铬、纯钛与钴铬的极化电阻之间具有统计学差异(p<0.05),而镍铬与钴铬的极化电阻没有统计学差异(p>0.05)。三种材料在人工唾液中均具有良好的耐腐蚀特性,它们的耐蚀性顺序是纯钛>钴铬合金>镍铬合金。 The corrosion resistance of commercially pure Ti (cp Ti), CoCr alloy and NiCr alloy in artificial saliva (AS) was studied by electrochemical methods. One-way ANOVA with SPSS 11.0 software package was used for statistical analysis. The results show that the order of Eocp was cp Ti G NiCr G CoCr,the order of Ecorr was cp Ti〈NiCr 〈CoCr, the order of Jcorr was cp Ti GCoCr GNiCr , the order of Rp was cp Ti GCoCr GNiCr. The Eocp, Ecorr and Jcorr were statistical significance among them (p〈0. 05). The Rp of cp Ti was significantly higher than that of CoCr and NiCr (p〈0. 05), the Rp of CoCr was higher than that of NiCr but not significant (p〉 0. 05). The results suggested that the cp Ti, CoCr and NiCr alloys showed a great corrosion resistance.
出处 《腐蚀与防护》 CAS 北大核心 2012年第11期984-986,共3页 Corrosion & Protection
关键词 镍铬合金 钴铬合金 纯钛 电化学 腐蚀性 CoCr alloy NiCr alloy titanium electrochemistry corrosion resistance
  • 相关文献

参考文献8

  • 1Upadhyay D, Panchal M A, Dubey R S, et al. Corrosion of alloys used in dentistry..A review[J]. Materials Science and Engineering: A, 2006,432 (1-2): 1 - 11.
  • 2Wataha J C. Biocompatibility of dental casting alloys: a review[J]. J Prosthet Dent, 2000,83 (2) - 223- 234.
  • 3胡滨,张富强.表面涂层技术对镍铬合金耐蚀性能的影响[J].上海口腔医学,2003,12(2):132-135. 被引量:17
  • 4裘松波,曹风华,孙占波.动电位极化技术在口腔修复材料腐蚀测定中的应用[J].第三军医大学学报,2001,23(2):227-229. 被引量:13
  • 5Shahabi M, Jahanbin A, Esmaily H, et al. Corrosion behaviour of a dental alloy in some beverages and drinks[J]. J Clin Pediatr Dent, 2011,35 (4) : 429-432.
  • 6Laurent F,Grosgogeat B, Reclaru L, et al. Comparison of corrosion behaviour in presence of oral bacteria[J]. Biomaterials, 2001,22 ( 16 ) : 2273-2282.
  • 7Ameer M A, Khamis E, Al-Motlaq M. Electrochemical behaviour of recasting Ni-Cr and Co-Cr non-precious dental alloys [J]. Corrosion Science, 2004, 46 ( 11 ) :2825-2836.
  • 8高勃,严晓东,陈静,汤慧萍,黄瑜.激光立体成形Ti-Zr合金腐蚀性能研究[J].实用口腔医学杂志,2006,22(3):325-328. 被引量:6

二级参考文献22

  • 1陈安玉.口腔种植学[M].成都:四川科学技术出版社,1993.106.
  • 2Wataha JC, Lockwood PE, Khajotia SS, et al. Effect of pH on element release from dental casting alloys [J]. J Prosthet Dent, 1998, 80: 691-698.
  • 3Aziz-Kerrzo M, Conroy KG, Fenelon AM, et al. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials[J]. Biomaterials, 2001, 22:1531-1539.
  • 4Jorgenson DS, Centeno JA, Mayer MH, et al. Biologic response to passive dissolution of titanium craniofacial microplates [J].Biomaterials, 1999,20: 675-682.
  • 5Bumgardner JD, Lucas LC. Corrosion and cell culture evaluation of nickel-chromium dental casting alloys[J]. J Appl Biobater, 1994,5: 203-213.
  • 6Wataha JC. Principles of biocompatibility for dental practitioners[J]. J Prosthet Dent, 2001, 86: 203-209.
  • 7Wataha JC, Malcolm CT. Effect of alloy surface composition on release of element from dental casting alloys [J]. J Oral Rebabil, 1996, 23: 583-589.
  • 8Messer RLW, Lucas LC. Cytotoxicity evaluations of ions released from nickel-chromium dental alloys[J]. J Dent Res, 1996, 75: 225.
  • 9Watanabe I, Hai K, Tanaka Y, et al. In vitro corrosion behavior of cast iron-platinium magnetic alloys [J]. Dent Mater, 2001, 17:217-220.
  • 10Wataha J C,J Prosthet Dent,2000年,83卷,2期,223页

共引文献33

同被引文献30

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部