期刊文献+

ESPRESSO钠回路管道的应力分析和计算

ESPRESSO Sodium Loop Pipe Stress Analysis and Calculation
下载PDF
导出
摘要 由意大利引入ESPRESSO钠回路是为意大利的PEC快堆进行燃料元件考验和热冲击试验而建造的,该台架的寿命和性能已不是原始设计值。同时由于是高温设施,经过拆卸和重新安装,特别是焊接的质量和检验的标准不同,对设备的安全运行均有重要影响。本工作对ESPRESSO钠回路管道应力进行分析和计算,判断回路管道的应力分布水平,最终通过调整恒力吊架来保证回路的运行安全。 ESPRESSO sodium loop was made for the test and thermal shock which was for the Italy PEC Fast Reactor fuel components.More than 10 years has passed since the loop was imported from Italy,and its life-span and performance are not assured as same as the design parameters.At the same time the disassemble and installing of the loop influenced the safety of the loop operation badly which was high-temperature plant because of the difference of the jointing quality and inspection standard.Through the pipeline stress analysis and calculation,we can verdict the distribution of the pipeline stress,and the loop operation safety is ensured by adjusting the constant hangers.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2012年第B09期406-410,共5页 Atomic Energy Science and Technology
关键词 回路 管道 应力 loop pipeline stress
  • 相关文献

参考文献2

  • 1王致祥,梁志国孙国模,等.管道应力分析与计算[M].北京:水利电力出版社,1982.
  • 2SDGJ6-78火力发电厂汽水管道应力计算技术规定[S].北京:水力电力出版社,1979.

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部