铱-192工业探伤源对典型居民区的剂量计算 被引量:1

Radiation Dose Calculation of Typical Residential Area Induced by Industrial Radiography Indium-192 Source
下载PDF
导出
摘要 根据中国原子能科学研究院铱-192工业探伤源物理参数,采用蒙特卡罗方法程序(MCNP)计算了铱-192源在典型居民区的空间剂量分布和居民的吸收剂量率。结果表明:水平方向1 200 cm处在"有"和"无"混凝土墙防护情况下的吸收剂量率分别为12.200 0和2 090.000 0μGy/h,垂直方向吸收剂量率随位置呈指数衰减;铱-192源所存放2#居民楼3楼层以上住户的吸收剂量率低于USNRC限值。计算结果将为铱-192放射源事故的评估和受照人群的医学治疗提供参考。 Space dose distribution and inhabitant absorbed dose rate in typical residential area induced by indi- um - 192, which based on physics parameter of China Institute of Atomic Energy industrial radiography indium -192 source is calculated by Monte Carlo methods code MCNP. Results show that horizontal absorbed dose rate with concrete wall is 12. 200 0 μGy/h and without it is 2 090. 000 0 μGy/h, vertical absorbed dose rate at- tenuates with exponential law, that absorbed dose rate of inhabitant who bide over 3 floor in 2# dwelling house is under the limit value of USNRC. The calculated results will provide a reference for evaluation of indium - 192 source accident and therapeutic treatment of irradiated crowd.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2012年第8期977-980,共4页 Nuclear Electronics & Detection Technology
基金 湖南省核技术及应用重点学科 放射性测量与防护技术湖南省高校科技创新团队资助
关键词 铱-192源 居民区 吸收剂量率 MCNP程序 indium- 192 source residential area absorbed dose rate MCNP code
  • 相关文献

参考文献8

  • 1陈秉忠,刘德荣,张志永,等.铱-192γ射线探伤装置及其应用[J].中国电力,1984,(5):28-30.
  • 2中国科学器材网.Ts-1Aγ射线探伤机[EB/OL].http://www.sciequip.com.cn/product.asp?SubProductID=18801,2011.
  • 3央视”焦点访谈”.“铱-192”之谜[EB/OL].ht-tp://news.sina.com.cn/c/2005-11-16/00208306458.shtml,2010.
  • 4中国原子高科股份有限公司.铱-192工业探伤源[EB/OL].http://www.atom-hitech.com/product_cgpro_info_detail.asp?id=162,2011.
  • 5C. D. Armon,II. Criticality Calculations with MCNP: A Primer [R]. LA - 12827 - M,Los Alamos National Laboratory, August, 1994.
  • 6NIST. X- Ray Mass Attenuation Coefficients [ EB/ OL ]. http ://physics. nist. gov/PhysRefData/Xray- MassCoef/tab2. html, 2011.
  • 7蔡敏芹,林大全,郭祚达,王远萍,王兵.中国人辐照仿真人体模型及人体器官数学模型[J].中国医学影像技术,2005,21(9):1464-1467. 被引量:14
  • 8USNRC. NRC Regulatory Guides [ EB/OL]. http:// www. nrc. gov/reading - rm/doc - collectiona/reg - guides/, 1996.

二级参考文献9

  • 1张良安,王丹,徐志勇,戴光复,耿秀生,苏旭.放射外照射事故剂量重建中的蒙特卡罗模拟方法[J].中华放射医学与防护杂志,2004,24(6):565-568. 被引量:5
  • 2钱竞光.体操动作中的多体系统动力学原理[J].体育与科学,1995,16(5):16-19. 被引量:5
  • 3Farrelly J. Principles and applications of radiation therapy [J].Clinical Techniques in Small Animal Practice, 2003,18(2) :82-87.
  • 4ICRU REPORT 48. Phantoms and computational models in thera py, diagnosis and protection. Issued: 15 June 1992. International Commission Radiation Units and Measurements.
  • 5中国计量测试学会 电离辐射专业委员会.辐射剂量学常用数据[M].北京:中国计量出版社,1987.187,302-306.
  • 6Michael M, John D, Haris V, et al. A method of estimating fetal dose during brain radiation therapy [J]. Int J Radiat Oncol Biol Phys, 1999,44(2) :455-459.
  • 7Bliznakova K, Kolitsi Z, Pallikarakis N. A Monte Carlo based radiotherapy simulator [J]. Nuclear Instruments and Methods in Physics Research B, 2004,222(3-4) :445-461.
  • 8Andreo P. Monte Carlo application in radiotherapy [J] . Radiation Physics and Chemistry, 1998,53(3):350-351.
  • 9李开宝,罗素明,程金生.放疗剂量学的质量保证[J].中华放射医学与防护杂志,1997,17(5):352-354. 被引量:16

共引文献13

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部