摘要
首先对转换结构应用到外套增层改造中的发展概况进行总结,并针对实际工程对一种新型"加腋墙"转换结构的使用进行了讨论;其次应用SAP2000对该工程建立有限元模型,对整体外套增层结构和原砖混结构进行分析。增层前后对比分析结果表明,整体外套增层改造使原结构的层间位移角、层间剪力等都有明显增大,应进行必要的抗震加固,以保证整体结构的抗震性能。另外,使用"加腋墙"转换结构的外套增层结构刚度比较均匀,有利于结构的整体抗震性能。
Firstly the development of transfer structures applying to extension-story-adding buildings is summarized,and in connection with the actual project,a new type of axillary-adding wall transfer structure is discussed.Secondly,the SAP2000 is used to research the dynamic behavior of this structural system,and analysis of the extension-storey-adding building and existing masonry structure are conducted.The results of comparison indicate that the lateral displacement and drift angle have a significant growth after extension story adding,so the necessary seismic strengthening measures are needed to ensure the overall seismic behavior.In addition,the transfer structure used in practical project is good at the seismic behavior of the whole structure.
出处
《施工技术》
CAS
北大核心
2012年第11期62-65,共4页
Construction Technology
基金
国家自然科学基金(51008184)
关键词
改造
外套框架增层
有限元分析
抗震性能
reconstruction
extension-storey-adding
finite element analysis
seismic behavior