摘要 密肋复合墙结构采用预制装配式或现砌现浇方法建造时,其内部密肋复合墙与外部隐形框架之间可以采用三种连接构造形式。为研究不同连接构造形式对密肋复合墙体抗震性能的影响,对3片不同连接方式的1/2比例墙体试件进行低周反复荷载试验,总结了密肋复合墙体试件的破坏过程和破坏特点,分析3片墙体在承载力、滞回曲线、刚度、延性等方面的差异,并对其主要影响原因进行讨论。试验研究表明:当钢筋、混凝土及砌块用量基本相同时,三种不同连接构造形式墙体在破坏形态和延性方面差别不大,但其各自抗震性能并不相同,采用现砌现浇式制作的密肋复合墙抗剪承载力和刚度明显优于预制装配式。 The multi-grid composite wall structure can be constructed with prefabrication assembly construction method or cast-in-place method,and three connection and construction forms can be used in the structure between the inner composite wall and the outer frame.In order to find out how different connection and construction forms influence the seismic performances of multi-grid composite wall,cyclic reversed loading tests were conducted on 3 composite wall specimens of half scale.The failure process and features of specimens are introduced,and the seismic performance such as bearing capacity,hysteretic curve,stiffness,ductility were investigated,and the main reasons are discussed.Test results show that with the same amount of concrete,steel bar and blocks,the seismic performances of the walls with different connection and construction forms are different,and the bearing capacity and stiffness of the wall made by cast-in-place method are better than that of the wall made by prefabricated method,and the differences in failure characters and ductility ability among three type walls are minimal.
出处 《建筑科学》 北大核心 2012年第11期38-42,共5页 Building Science
基金 国家自然科学基金(50878021) "十一五"国家科技支撑计划(2006BAJ04A02-05)
关键词 密肋复合墙 连接构造形式 预制装配式 现砌现浇式 抗震性能 multi-grid composite wall connection and construction form prefabrication and assembly construction cast-in-place seismic performance
  • 相关文献

参考文献7

  • 1GB50011-200l,建筑结构抗震设计规范[S].
  • 2Liu P. , Yao Q.F. Dynamic reliability of structures : the example of multi-grid composite walls [ J ]. Structural Engineering and Mechanics, 2010, 36(4):463-479.
  • 3郭猛,姚谦峰.框架-密肋复合墙结构新体系研究[J].地震工程与工程振动,2009,29(5):73-78. 被引量:27
  • 4郭猛,姚谦峰,袁泉,李鹏飞.框架-密肋复合墙体抗震性能试验研究[J].建筑结构学报,2011,32(3):50-56. 被引量:19
  • 5河北省建设厅.DB13(J)64-2006密肋壁板结构技术规程[S].
  • 6周铁钢,张荫,姚谦峰.密肋壁板轻框结构体系施工技术[J].工业建筑,2003,33(1):23-25. 被引量:9
  • 7Xia Lei, Yao Qianfeng, Chang Peng, et al. Seismic safety evaluation analysis of a new building structure with multi-ribbed composite wall structure [ C ]. Proceedings of international conference on Earthquake Engineering: The First Anniversary of Wenchuan Earthquake, 2009 : 325 ~ 328.

二级参考文献16

  • 1崔鸿超.日本兵库县南部地震震害综述[J].建筑结构学报,1996,17(1):2-13. 被引量:54
  • 2周晓夫,程绍革,肖伟,刘经伟,郭明.中国地质博物馆抗震鉴定与加固设计[J].工程抗震与加固改造,2006,28(2):56-60. 被引量:1
  • 3童岳生.砖填充墙钢筋混凝土框架在水平荷载作用下结构性能的试验研究[J].西安冶金建筑学院学报,1982,(1):1-13.
  • 4河北省建设厅.DB13(J)64-2006密肋壁板结构技术规程[S].
  • 5何明胜.型钢混凝土边框柱密肋复合墙体抗震性能及设计理论研究[D].西安:西安建筑科技大学,2008.
  • 6Xia Lei, Yao Qianfeng, Chang Peng, et al. Seismic safety evaluation analysis of a new building structure with multi-ribbed composite wall structure [ C ] // Proceedings of International Conference on Earthquake Engineering: The First Anniversary of Wenchuan Earthquake. Chengdu: Southwest Jiaotong University Press, 2009 : 325-328.
  • 7Liu P, Yao Q F. Dynamic reliability of structures: the example of multi-grid composite walls [ J ]. Structural Engineering and Mechanics, 2010, 36(4) : 463-479.
  • 8GB50011-2001.建筑结构抗震设计规范[S].[S].,..
  • 9西安建筑科技大学建筑工程新技术研究所.密肋壁板轻型框架结构理论与应用研究[R].西安:西安建筑科技大学,2000.
  • 10孙景江,马强,石宏彬,孙忠贤.汶川地震高烈度区城镇房屋震害简介[J].地震工程与工程振动,2008,28(3):7-15. 被引量:45

共引文献51

同被引文献68

引证文献7

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部