摘要 通过冷态PDA试验,对不同中心风率下径向浓淡旋流煤粉燃烧器出口的速度及浓度场进行了测量,得出了中心风对燃烧器出口气固流动特性的影响;工业性热态试验研究了中心风对燃烧器出口温度及烟气气氛的影响,得出了中心风对燃烧和NO。排放的影响规律,为设计和运行提供了参考性依据。 The cold experiments measured by a laser phase dopple particle analyzer(PDA) and pilot tests are done about effects of the central air on the performance of the radials bias combustion swirl Pulverized coal bumer(RBC). The cold experiments show that the cental air has great influence on the flow pattern and particle concentration at the swirl burner exit. Pilot tests show that the central air has great influence on the ed coal combustion. In addition, the central air has little contribution to the NOx. emission.
出处 《机械工程学报》 EI CAS CSCD 北大核心 2000年第6期63-67,共5页 Journal of Mechanical Engineering
基金 国家"九五"重点科技攻关 国家教委博士点基金
关键词 旋流煤粉燃烧器 煤粉燃烧 锅炉 中心风 性能 Swirl burner Pulverized coal combustion Gas-particle two phase flows PDA measurement NO_x control
  • 相关文献

参考文献2

  • 1钟北京,动力工程,1995年,15卷,5期,18页
  • 2秦裕琨,一种径向浓淡旋流燃烧器,中国专利,ZJ932 44359.1,1993年

同被引文献38

  • 1赵兴浩,邓兵,陶然.分数阶傅里叶变换数值计算中的量纲归一化[J].北京理工大学学报,2005,25(4):360-364. 被引量:125
  • 2李争起,陈智超,孙锐,吴少华.适用于燃用贫煤1025 t/h锅炉的中心给粉旋流燃烧器[J].机械工程学报,2006,42(3):221-226. 被引量:11
  • 3李争起,孙锐,陈智超,等.一种中心给粉旋流煤粉燃烧器[P].中国发明专利,03111101.7.
  • 4王春昌,屈卫海.一种中心风可调的直流燃烧器设想[J].热力发电,2007,36(12):41-43. 被引量:2
  • 5LIANG Zengying, MA Xiaoqian, TANG Yuting, et al. The energy consumption and environmental impacts of SCR technology in China[J]. Applied Energy, 2011, 88(4): 1120-1129.
  • 6GAO Xiaotao, ZHANG Mingyao. NOx emissions of an opposed wall- fired pulverized coal utility boiler[J]. Asia-Pacific Journal of Chemical Engineering, 2010, 5(3): 447-453.
  • 7LI S, XU T, HUI S, WEI X. NOx emission and thermal efficiency of a 300MWe utility boiler retrofitted by air staging[J]. Applied Energy, 2009, 86(9): 1797-1803.
  • 8COSTA M, AZEVEDO J. Experimental Characterization of an industrial pulverized coal-fired furnace under deep staging conditions[J]. Combustion Science and Technology, 2007, 179(9): 1923-1935.
  • 9JING J, LI Z, LIU G, et al. Measurement of gas species, temperatures, coal burnout, and wall heat fluxes in a 200 MWe lignite-fired boiler with different overfire air damper openings[J]. Energy & Fuels, 2009, 23(7): 3573-3585.
  • 10LI Z, LIU G, CHEN Z, et al. Effect of angle of arch-supplied over fire air on flow, combustion characteristics and NOx emissions of a down-fired utility boiler[J].Energy, 2013, 59: 377-386.