期刊文献+

房间隔缺损患者行冠状动脉CTA检查的个性化对比剂注射方案研究 被引量:9

Individual contrast medium injection protocol for coronary CT angiography in atrial septal defect patients
下载PDF
导出
摘要 目的:探讨房间隔缺损患者行冠状动脉CTA检查的理想对比剂注射方案。方法:将连续90例拟行介入治疗或外科手术治疗中老年房间隔缺损患者,于术前行冠状动脉CTA检查,依据不同的对比剂注射方案将患者随机分为3组。A组:单期相注射方案(仅注射基础量对比剂,不注射生理盐水);B组:双期相注射方案(先注射基础量对比剂,后以40mL生理盐水冲洗);C组:三期相注射方案(先注射基础量对比剂,后注射30%生理盐水与对比剂的混合物30mL,最后注射40mL生理盐水冲洗)。基础量对比剂按1mL/kg计算,注射流率均为5.0mL/s。比较3组方案CTA图像上冠状动脉及左、右心系统的CT值及房间隔缺损的可评估性。结果:3组患者在平均年龄、体重及心率方面差异无显著性意义。各组患者冠状动脉、升主动脉及左心房、左心室的CT值差异无显著性意义(P>0.05),但各组右心房、右心室及肺动脉的CT值均数大于250HU;此外,B组对比剂用量明显低于其它2组(P<0.05),房间隔缺损量化评分高于C组(P<0.05)。结论:双期注射方案由于对比剂用量减少,利于房间隔缺损评估,因而是房间隔缺损患者行冠状动脉CTA检查的理想的对比剂注射方案。 Objective:To determine the individual protocol for dual-source CT contrast-enhanced cardiac imaging for better visualization of both coronary artery and atrial septal defect. Methods:A total of ninety consecutive patients were in- cluded in this prospective study. Each 30 patients were assigned to use a different contrast protocol., group Ⅰ.. monophasic protocol (basic contrast injection without saline chaser) with a single-syringe injector; group Ⅱ; biphasic protocol (basic contrast injection + saline chaser 40mL) with a dual-syringe injector; group Ⅲ..triphasic protocol (basic contrast media+ 30% saline-to-contrast medium mixture 30mL+ saline chaser 40mL) with a dual-syringe injector. The basic contrast media was 1.0ml/kg. Two radiologists rated the visualization of right and left heart structures, coronary artery, ASD (atrial septal defect) and the degree of streak artifacts. One observer performed attenuation measurements of the cardiac chambers and of the coronary arteries. Data were analyzed with one-way analysis of variance and LSD post-hoc multiple comparison proce- dures. Results: Data for 33 men and 57 women (mean age, 58 years) were included, the groups were comparable in mean age, body weight and heart rate. Among the three groups, there were no significant differences for the mean medium atte- nuation of the left heart and the coronary arteries among the three groups (p〉0.05). Mean contrast medium attenuation in the right heart was significantly (P〈0. 001) higher in the group 3 than the other groups, while the 250HU of CT values were met in right ventriculars and pulmonary arteries in all groups, and the delineation of ASD received significantly higher scores (p〈0.05 LSD test) in the group 2 than the groups 3 for the latter's diminished difference in contrast medium con- centration between the left and the right atrium. Conclusion:Biphasic protocol are superior to the other protocols for redu- cing the amount of contrast media and improving the delineation of ASD, and it is advisable for coronary CT angiography with atrial septal defect patients.
机构地区 中国医学科学院
出处 《放射学实践》 2012年第11期1217-1220,共4页 Radiologic Practice
关键词 体层摄影术 X线计算机 冠状动脉疾病 先天性心脏病 对比剂 Tomography,X-ray computed Coronary artery diseases Congenital heart diseases Contrast media
  • 相关文献

参考文献12

  • 1Ramos-Duran LR, Kalafut JF, Hanley M, et al. Current contrast media delivery strategies Ior cardiac and pulmonary multidetector row computed tomography angiography[J]. J Thorac Imaging,: 2010,25(4) :270-277.
  • 2Saremi F, Channual S, Raney A, et al. Imaging of patent foramen, ovale with 64-section multidetector CT[J]. Radiology, 2008,249 (2) :483-492.
  • 3Ko SF,Liang CD,YipHK,et al. Amplatzer septal occluder closure of atrial septal defect evaluation of transthoracic echocardio- graphy, cardiac CT, and transesophageal echocardiography [J]. AJR,2009,193(6):1522-1529.
  • 4宋会军,徐仲英,蒋世良,赵世华,吕滨,张戈军,凌坚,郑宏,金敬琳,李世国,吴文辉,胡海波,徐亮.中老年房间隔缺损患者介入治疗前心脏CT检查的价值[J].中华心血管病杂志,2011,39(9):830-835. 被引量:12
  • 5Wuesta W,Zunkera C,Katharina A, et al. Functional cardiac CT imaging:a new contrast application strategy for a better visualiza- tion of the cardiac chambers[J]. Eur J Radiol, 2008,68(3) : 392-397.
  • 6Lu JG, Lv B,Chen XB, et al. What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography? [J]. Eur J Radiol,2010,75(2) :159-165.
  • 7Kim DJ,Kim TH, Kim SJ, et al. Saline flush effect for enhance- ment of aorta and coronary arteries at multi-detector CT coronary angiography[J]. Radiology, 2008,246 (1) : 110-115.
  • 8Kerl JM, Ravenel JG, Nguyen SA, et al. Right heart: split-bolus injection of diluted contrast medium for visulization at coronary CT angiography[J]. Radiology, 2008,247 (2) : 356-364.
  • 9Orlandini F, Boini S, Iochum-Duchamps S, et al. Assessment of the use of a saline chaser to reduce the volume of contrast medium in abdominal CT[J] AJR, 2006,187(2) : 511-515.
  • 10Ko SF,Liang CD,Yip HK, et al. Amplatzer septal occluder clo- sure of atrial septal defeet: evaluation of transthoraeic echoear diography, eardiae CT, and transesophageal eehoeardiography [J]. AJR, 2009,193(6) : 1522-1529.

二级参考文献5

共引文献11

同被引文献75

  • 1赵世华,王诚,蒋世良,黄连军,徐仲英,凌坚,郑宏,张戈军,吕滨,吕建华,金敬琳,闫朝武,王浩,刘延玲,戴汝平.成人继发孔型房间隔缺损形态学特点及其对经导管封堵术的影响[J].中华心血管病杂志,2006,34(11):987-990. 被引量:13
  • 2Rao PS,Langhough R. Relationship of echocardiographic, shunt flow and angiographic size to the stretched diameter of the atrial septal defect. Am Heart J, 1991,122:505-508.
  • 3Johri AM, Witzke C, Solis J, et al. Real-Time Three-Dimensional Transesophageal Echocardiography in Patients with Secundum Atrial Septal Defects : Outcomes following Transcatheter Closure. J Am Soc Echocardiogr, 2011,24:431-437.
  • 4Seo JS,Song JM, Kim YH, et al. Effect of atrial septal defect shape evaluated using three-dimensional transesophageal echocardiography on size measurements for percutaneous closure. J Am Soc Echocardiogr, 2012,25:1031-1040.
  • 5Zanchetta M, Onorato E, Rigatelli G, et al. Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect: a new e~cient device selection method. J Am Coil Cardiol, 2003,42 : 1677-1682.
  • 6易亚苏.椭圆定理[EB/OL].http://blog.sina.tom.cn/s/blog_476215d2010005dd.html,2006-08-25.
  • 7Wang JK, Tsai SK, Lin SM, et al. Transcatheter closure of atrial septal defect without balloon sizing. Catheterization and cardiovascular interventions. Catheter Cardiovasc Interv, 2008, 71:214-221.
  • 8Carlson KM,Justino H, O'Brien RE, et al. Transcatheter atrial septal defect closure: modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer scptal occluder. Catheter Cardiovasc Interv, 2005,66:390-396.
  • 9Sadeghian H, Hajizeinali A, Eslami B, et al. Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method. J Tehran Heart Cent, 2010,5:74-77.
  • 10Zanchetta M, Onorato E,Rigatelli G, et al. Intracardiacechocardiography-guided transcatheter closure of secundum atrialseptal defect : a new efficient device selection method. J Am CollCardiol,2003 ,42: 1677-1682.

引证文献9

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部