期刊文献+

流速的超声多普勒定量测量 被引量:4

A New Method for Quantitative Measurement of Blood Flow Velocity with Doppler Ultrasound
原文传递
导出
摘要 报道了一种超声多普勒血流速度定量测量的方法.叙述了任意位置精确测量血流速度的原理,以及反映血管走向夹角的计算方法.提出了按实际情况进行再校正以进一步提高测量流速精度的方法.给出了验证实验的结果,及该方法与准补偿法的比较. A new method for quantitative measurement of blood flow velocity with Doppler ultrasound is presented. The principle of the precise velocity measurement at any angle and the method of calculation of the angle are described. The re-correction based on the practice is applied to improve the precision of the velocity measurement. Experimental results and comparisons of the method with the quasi-compensation are also given too.
出处 《复旦学报(自然科学版)》 CAS CSCD 北大核心 2000年第2期163-166,173,共5页 Journal of Fudan University:Natural Science
关键词 超声多普勒 血流速度 准补偿法 再校正 测量 Doppler ultrasound blood flow velocity quasi-compensation re-correction
  • 相关文献

参考文献6

二级参考文献6

  • 1王威琪,J Cardiovascular Vltrasonography,1986年,5卷,289页
  • 2叶国凡,复旦学报,1986年,25卷,251页
  • 3邵谦明,1985年
  • 4王威琪,复旦学报,1982年,21卷,301页
  • 5王威琪,复旦学报,1981年,20卷,349页
  • 6K. Poots,Dr. R. S. C. Cobbold,K. W. Johnston,R. Appugliese,M. Kassam,P. E. Zuech,R. L. Hummel. A new pulsatile flow visualization method using a photochromic dye with application to Doppler ultrasound[J] 1986,Annals of Biomedical Engineering(3):203~218

共引文献10

同被引文献29

  • 1彭旗宇,高上凯.医学超声成像中的编码激励技术及其应用[J].生物医学工程学杂志,2005,22(1):175-180. 被引量:26
  • 2王威琪,余建国.关于超声血流速度的测试定标方法和系统[J].上海生物医学工程,1996,17(2):13-15. 被引量:9
  • 3张立明.人工神经网络的模型及其应用[M].复旦大学出版社,1992..
  • 4WANG W Q et al. Optimum position and quansicompensation approach for quantitative measurement of blood flow with Doppler ultrasound. J Cardiovascular Ultrasonography, 1986, 5(4):286.
  • 5WANG Wei-qi. A double beam Doppler ultrasound method for quantitative blood flow velocity measurement. Ultrasound in Med & Biol, 1982, 8(4):421.
  • 6LabVIEW Tutorial. July 2000 Edition, National Instruments, Co, Ltd, 2002.
  • 7RICHARDSON P, JOHN S. Design of a continuous wave Doppler ultrasonic flowmeter for perivascular bibliography application[J]. Med Biol Eng Comput, 1987,25 : 661-662.
  • 8UEMATSU S. Determination of volume of arterial blood flow buy an ultrasonic device [J ]. J Clin Ultrasound,1981, 9 : 209-212.
  • 9GILL R W. Measurement of blood flow by ultrasound:Accuracy and sources of error[J]. Ultrasound in med &Biol, 1985, 11:625-627.
  • 10SMITH C K, HUSSAIN R, DUERINCKX A, et al. Assurance of consistent peak-velocity measurements with a variety of duplex Doppler instruments [ J ]. Radiology,1990, 17 : 265-268.

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部