期刊文献+

床旁检验血糖仪与生化分析仪血糖测定结果比对分析 被引量:6

Comparison of POCT blood glucose meter with the automatic biochemical analyzer
下载PDF
导出
摘要 目的对中山医院床旁检验(POCT)血糖仪与全自动生化分析仪血糖测定结果进行比对分析和偏倚评估,以保证血糖仪检测结果的一致性。方法参照《便携式葡萄糖仪血液葡萄糖测定指南》,采集肝素钠抗凝静脉血10份,血糖水平分布在3.20~25.81mmol/L。在POCT血糖仪和生化分析仪上重复测定3次,以生化仪为靶仪器,计算相对偏倚。结果 42台血糖仪中的38台与生化分析仪测定值相对偏倚在1%~13%,符合要求。结论通过对中山医院POCT血糖仪与生化分析仪血糖测定结果的比对和偏倚评估,评价血糖仪检测的准确性,以更好地规范医院床旁血糖仪的使用。 Objective To analyze the comparison and bias of POCT blood glucose meter with the automatic biochemical analyzer for ensuring the consistency of the blood glucose meter test results.Methods sodium heparin anticoagulant blood of 10 copies were acquired,distribution of blood glucose levels between 3.20-25.81 mmol/L.Measurements were three times repeatedly on the POCT glucose meters and biochemical analyzer,biochemical analyzer for the target instrument to calculate the relative bias.Results Relative bias of 38 of the 42 blood glucose meters were from 1% to 13.0%,in line with requirements.Conclusion The hospital POCT glucometer biochemical analyzer glucose can evaluate the accuracy of blood glucose meter testing,which can regulate the use of blood glucose meter in hospital.
出处 《检验医学与临床》 CAS 2012年第22期2787-2788,共2页 Laboratory Medicine and Clinic
基金 中山市卫生局科研基金项目(2010045)
关键词 床旁检验 血糖 比对 偏倚 point of care testing(POCT) blood glucose comparison test bias
  • 相关文献

参考文献6

二级参考文献15

  • 1李红.影响快速血糖检测法准确性的因素与对策[J].中国实用护理杂志,2004,20(12):15-16. 被引量:59
  • 2唐贯文,王丽娟,利金彩,朱文娟.烧伤患者静脉血糖与末梢血糖的关系探讨[J].中国实用护理杂志(中旬版),2006,22(5):12-13. 被引量:14
  • 3American Diabetes Association. Consensus statement on self-monitoring of blood glucose [ J ]. Diabetes Care, 1987,10( 1 ) :95-99.
  • 4American Diabetes Association. Bedside blood glucose monitoring in hospitals [ J ]. Diabetes Care, 2004, 27 (Suppl 1 ) :S104.
  • 5G13/T19634-2005.体外诊断检验系统自测用血糖监测系统通用技术条件[S].
  • 6Bastanhagh MH, Shirvan AR, Heshmat R, et al. Evaluation of the efficacy of blood glucose home monitoring devices [ J]. Med Sci Monit, 2007, 13 (3) :PI1-PI6.
  • 7Skeie S, Thue G, Nerhus K, et al. Instruments for self-monitoring of blood glucose: comparisons of testing quality achieved by patients and a technician [J]. Clin Chem, 2002, 48(7) : 994-1003.
  • 8Solnica B, Naskalski JW, Sieradzki J. Analytical performance of glucometers used for routine glucose self- monitoring of diabetic patients [ J ]. Clin Chim Acta, 2003,331 (1-2) :29-35.
  • 9Stahl M, Brandslund I. Measurement of glucose content in plasma from capillary blood in diagnosis of diabetes mellitus[J]. Scand J Clin Lab Invest ,2003, 63(6) : 431-440.
  • 10Christopher P: Price, point-of-care-testing. AACC, 1999.

共引文献99

同被引文献48

  • 1万德胜.微机血糖仪测定血糖的方法学评价[J].临床和实验医学杂志,2007,6(3):94-95. 被引量:6
  • 2康熙雄.床旁即刻临床检测的规范化趋向[C].中华医学会第七次全国检验医学学术会议,2008:76-78.
  • 3沈丽.末梢血糖与血清血糖一致性的评价.临床诊断,2012,7:50-52.
  • 4卫生部办公厅.医疗机构便携式血糖检测仪管理和临床操作规范(试行)[Z].2010-12-30.
  • 5Liu YP,Tian ZM, Xie B, et al.Application of biological enzyme heat an- alyzer measurement of fast blood glucose analysis[J].Joumal of Clinical and Laboratory Medicine,2013,21(8):666-667.
  • 6Louie R,Ferguson W,Sumner S,et al.Effects of dynamic temperature and humidity stresses on point-of-care glucose testing for disaster care[J]. Disaster Med Public, 2012,6 (3) : 232-240.
  • 7潘宝龙.《医疗机构便携式血糖检测仪管理和临床操作规范(试行)》解读.玉溪市第十届检验医学学术年会暨科技成果推广会论文汇编,2011.
  • 8徐建新,李福刚.POCT对传统医疗模式带来的新机遇[J].中华检验医学杂志,2007,30(12):1329-1331. 被引量:44
  • 9丁红香,徐晓杰,张美芬,倪莉.POCT血糖仪与生化分析仪血糖检测结果的比对试验及分析[J].中华检验医学杂志,2007,30(12):1374-1375. 被引量:48
  • 10中华人民共和国卫生部主编.医疗机构便携式血糖检测仪管理和临床操作规范(试行).北京:中华人民共和国卫生部,2010.

引证文献6

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部