期刊文献+

ITI种植体在3.0 T MRI检查中的伪影影响 被引量:5

Artifact Influence of ITI implants on 3.0 T MRI Examination
下载PDF
导出
摘要 目的探索不同体积ITI种植体在3.0T磁共振成像(MRI)检查中的伪影影响。方法将同一直径不同长度的两枚ITI种植体分别固定在志愿者两侧下颌骨皮肤表面,做MRI测试。磁共振仪磁场强度为3.0 T,采用TSE/EPI序列。结果两枚种植体都能在MRI检查中产生伪影,影响局部区域成像质量,其中体积较大的种植体产生的伪影更大。结论纯钛ITI种植体在MRI检查中,对其周围软组织成像有一定影响,并且伪影面积大小与种植体体积有关。 Objective To investigate the artifact influence of IT1 implants with different volumes on 3.0T MRL Methods Two ITI implants with the same diameter but different length are fixed on skin sttrfaee of the bilateral mandibular, then these volunteers are detected by MRI. The magnetic field intensity is 3.0 T, and TSE/EPI sequence is used. Results Both of implants produce artifacts on the MRI, which could affect image qualities of local area. And the implant with larger volume has bigger artifact. Conclusion Under MRI examination, the ITI implants with pure titanium has certain influence on imagings of surrounding soft tissues. And the areas of the artifacts are relate to implant volume.
出处 《中国医疗设备》 2012年第11期160-162,共3页 China Medical Devices
关键词 磁共振成像 ITI种植体 伪影 MRI ITI implants arctifact
  • 相关文献

参考文献20

  • 1Yasar Ozkan,Mutlu Ozcan,Yasemin Kulak-Ozkan,et al.Three- year treatment outcomes with three brands of implants placed in the posterior maxilla and mandible of partially edentulous patients.[J].J Prosthet Dent,2007,(97):78-84.
  • 2Curtis MB,Thomas G,Wilson J,et al.Minimum criteria for immediate provisionalization of single-tooth dental implants in extraction sites:a 1-year retrospective study of 100 consecutive cases[J].J Oral MaxiUofac Surg,2011,(69):491-497.
  • 3Martin AD,Driscoll CL,Wood CP,et al.Safety evaluation of titanium middle ear prostheses at 3.0 tesla[J].Otolaryngology- Head and Neck Surgery,2005,132(4):537-542.
  • 4刘广顺,任庆云,王瑶,刘倩峰,张晋弘,李庆星.口腔固定修复金属材料对MRI影像的影响[J].实用口腔医学杂志,2010,26(2):265-267. 被引量:16
  • 5Richard J Hodgson. The basic science of MRl[J].Orthopaedics and Trauma,2011,25 (2): 119-130.
  • 6倪萍,陈自谦,张鲁闽,马继民.3T磁共振的特点及其质量控制策略[J].中国医疗设备,2009,24(12):121-124. 被引量:19
  • 7尹建忠.3T高场磁共振设备的常见伪影:原理、表现与对策[J].磁共振成像,2010,1(4):291-294. 被引量:15
  • 8Willinek WA,Schild HH.Clinical advantages of 3.0 T MRI over 1.5 T[J].European Journal of Radiology,2008,65(1):2-14.
  • 9Masakatsu Tsurusakia,Richard CS,Kazuro Sugimurab,et al.Quantitative and qualitative comparison of 3.0 T and 1.5 T MR imaging of the liver in patients with diffuse parenchymal liver disease [J].European Journal of Radiology,2009,72(3):314-320.
  • 10Juan Alvarez-Linera.3 T MRl:Advances in brain imaging[J]. European Journal of Radiology,2008,67(3):415-426.

二级参考文献85

共引文献71

同被引文献65

  • 1王威,姜波,吴宣,孙建军.三种烤瓷合金材料对磁共振成像的影响[J].中国医学科学院学报,2010,32(3):276-279. 被引量:5
  • 2刘玉华,孙樱琳.固定义齿修复材料对MRI图像的影响[J].现代口腔医学杂志,2005,19(6):588-589. 被引量:19
  • 3王东胜.三种特殊染色法显示不脱钙骨切片中新生骨的比较研究[J].中华老年口腔医学杂志,2006,4(3):139-140. 被引量:17
  • 4Sasaki Y, Akutagawa M, Emoto T, et al. Theoretical study of evalua- tion method for MRI metal artifact [C]. Engineering in Medicine and Biology Society(EMBC), 2013 35th Annual International Conference of the IEEE.Osaka: IEEE, 2013: 1073-1076.
  • 5王成洁,武丽春,康庆,等.两种种植系统和烤瓷冠在3.0T磁共振检查中的伪影影响[J]协和医学杂志,2013,4(1):35-38.
  • 6Taniyama T, Sohmura T, Etoh T, et al. Metal artifacts in MRI from non-magnetic dental alloy and its FEM analysis [J]. Dent Mater J, 2010, 29: 297-302.
  • 7Mathew CA, Mailer S, Maheshwaran. Interactions between magneti- cresonance imaging and dental material. J Pharm Bioall Sci, 2013,5: 113-616.
  • 8Starc ukova J, Starc uk Jr Z, Hubalkova H, et al. Magnetic suscepti- bility and electrical conductivity of metallic dental materials and their impact on MR imaging artifacts [J]. Dental Materials,2008, 24 (6) : 715-723.
  • 9Suh JS,Jeong EK, Shin KH,et al. Minimizing artifacts caused by metallic implants at MR imaging: Experimental and clinical studies [J]. A JR Am J Roentgenol, 1998, 171 (5): 1207-1213.
  • 10Dinesh R. Singh, Michael SM,Wilfred CG Peh,et al. Artifacts in Musculoskeletal MR Imaging [J]. Semin Musculoskelet Radiol, 2014, 18 (1) : 12-22.

引证文献5