摘要 回顾性分析行超声检查并经术后病理证实的9例肢体良性神经鞘瘤声像图特征及瘤体感兴趣区(ROI)内的横向剪切波速度(SWV)。二维灰阶超声显示瘤体长径(24.20±6.54)mm、短径(14.00±3.61)mm,瘤体长径大于短径(P<0.05);瘤体周围载瘤神经超声检出率77.78%;声触诊组织定量(VTQ)技术测量神经鞘瘤、肌肉组织及脂肪组织的SWV分别为(2.36±0.59)、(1.39±0.42)、(1.69±0.54)m/s,差异有统计学意义(P<0.05),进一步组间两两比较SWV超声测值:神经鞘瘤>脂肪组织>肌肉组织(P<0.01,P<0.05)。 9 cases with schwannoma in the extremity were examined by uhrasonography. Sonographic imagings fo- cused on the difference of ROI in VTQ values were performed retrospectively among the lesions, muscle tissues, and adipose tissues adjacent to the lesion. The longitudinal diameter of lesions was significantly greater than that of the transverse diameter, at (24. 20 -+ 6.54) mm and ( 14. 00 + 3.61 ) ram, respectively. The detectable rate of continuity with a nerve by uhrasonography was 77.78%. The SWV values (m/s) were: 2.36 ±0. 59 in lesions, 1.39±0.42 in muscle tissues, and 1.69 ±0.54 in adipose tissues respectively(P 〈0.05). Significant differences regarding SWV were observed among the lesions, muscle tissues and adipose tlssues(P 〈0.01, P 〈0.05).
出处 《安徽医科大学学报》 CAS 北大核心 2012年第12期1473-1475,共3页 Acta Universitatis Medicinalis Anhui
关键词 超声检查 肢体 良性神经鞘瘤 声辐射力脉冲成像 声触诊组织定量 ultrasonography extremity benign schwannoma acoustic radiation force impulse virtual touch tissuequantification
  • 相关文献

参考文献5

二级参考文献78

  • 1赵子卓,罗葆明.超声弹性成像基本原理及技术[J].中国医疗器械信息,2008,14(4):6-8. 被引量:74
  • 2Akihiko Osaki,Tomoyuki Kubota,Takeshi Suda,Masato Igarashi,Keisuke Nagasaki,Atsunori Tsuchiya,Masahiko Yano,Yasushi Tamura,Masaaki Takamura,Hirokazu Kawai,Satoshi Yamagiwa,Toru Kikuchi,Minoru Nomoto,Yutaka Aoyagi.Shear wave velocity is a useful marker for managing nonalcoholic steatohepatitis[J].World Journal of Gastroenterology,2010,16(23):2918-2925. 被引量:31
  • 3郭瑞军,南月敏,王明花,姚希贤,张文云,甄景琴,殷春霞.家兔脂肪肝肝压缩率、灰阶强度与声衰减对比研究[J].中国医学影像技术,2004,20(8):1186-1189. 被引量:11
  • 4Bravo AA, Sheth SG, Chopra S. Liver biopsy. NEngl J Med 2001; 344: 495-500.
  • 5Abdi W, Millan JC, Mezey E. Sampling variability on percu- taneous liver biopsy. Arch Intern Med 1979; 139: 667-669.
  • 6Bedossa P, Dargère D, Paradis V. Sampling variability of liver fibrosis in chronic hepatitis C. Hepatology 2003; 38: 1449-1457.
  • 7Cadranel JF, Rufat P, Degos F. Practices of liver biopsy in France: results of a prospective nationwide survey. For the Group of Epidemiology of the French Association for the Study of the Liver (AFEF). Hepatology 2000; 32: 477-481.
  • 8Maharaj B, Maharaj RJ, Leary WP, Cooppan RM, Naran AD, Pirie D, Pudifin DJ. Sampling variability and its influ- ence on the diagnostic yield of percutaneous needle biopsy of the liver. Lancet 1986; 1: 523-525.
  • 9Regev A, Berho M, Jeffers LJ, Milikowski C, Molina EG, Pyrsopoulos NT, Feng ZZ, Reddy KR, Schiff ER. Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection. Am J Gastroenterol 2002; 97: 2614-2618.
  • 10Anastasiou J, Alisa A, Virtue S, Portmann B, Murray-Lyon I, Williams R. Noninvasive markers of fibrosis and inflamma- tion in clinical practice: prospective comparison with liver biopsy. Eur J GastroenterolHepatol 2010; 22: 474-480.