摘要 通过建立X波段同轴磁控管模型,对起振过程进行PIC模拟,结果表明:当衰减瓷损耗角正切大于0.010时,起振过程中可能受干扰模影响,但均能正常工作;当选用损耗角正切为0.001或不具有衰减性能的材料时,磁控管可能无法正常工作。因此同轴磁控管中需要选用损耗角正切大于0.010的电介质材料。进一步对该磁控管进行冷态微波特性模拟研究,重点分析了磁控管主模、N/2-1干扰模在不同参数衰减瓷下的品质因数,模拟结果表明衰减瓷位置合理,当损耗角正切大于0.010时,对N/2-1模的吸收效果明显改善,验证了PIC模拟的结论。 PIC simulation is taken to get the oscillating process of the X band coaxial magnetron.Though the oscillating process would be affected by the spurious mode,the magnetron could work properly if the loss tangent of the attenuator exceeds 0.010.Otherwise the magnetron would be unable to work.So attenuators with loss tangent exceeding 0.010 are needed for coaxial magnetrons.The quality factors of the prime mode and N/2-1 mode in coaxial magnetrons with different attenuators are obtained.The results indicate that it would be effective to absorb N/2-1 mode if the loss tangent of attenuators exceeds 0.010,confirming the PIC results.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2012年第12期2889-2892,共4页 High Power Laser and Particle Beams
关键词 同轴磁控管 衰减瓷 损耗角正切 PIC模拟 coaxial magnetron attenuator loss tangent PIC simulation
  • 相关文献

参考文献9

  • 1孙翔,童德春,林郁正.X-波段轴耦合驻波电子直线加速管物理设计与研究[J].原子能科学技术,1998,32(4):294-298. 被引量:8
  • 2电子管设计手册编委会.磁控管设计手册[M].北京:国防工业出版社,1979.
  • 3Lemke R W, Genoni T C,Spencer T A. Three-dimensional particle-in-cell simulation study of a relativistic magnetron[J]. Physics of Plas-mas ,1999,6(2): 603-613.
  • 4Kim H J, Shin J U, Choi J J. Particle-in-cell code simulations on a rising-sun magnetron oscillator[J]. IEEE Trans on Plasma Sci, 2002,30(3):956-961.
  • 5陈彦,杨中海,雷文强.径向非均匀磁场下的磁控管工作性能模拟[J].强激光与粒子束,2005,17(9):1409-1413. 被引量:9
  • 6丁帅,贾宝富,朱兆君,李飞雪.一种5.8 GHz磁控管粒子模拟[J].强激光与粒子束,2009,21(8):1216-1220. 被引量:4
  • 7石明,鲁燕萍,刘征,高陇桥.微波管用衰减材料的研究[J].真空电子技术,2007,20(3):31-37. 被引量:9
  • 8Qiu Jiaqi, Chen Huaibi,Tang Chuanxiang. PIC simulation of the coaxial magnetron for low energy X-band linear accelerators[C]//Proc of1st International Particle Accelerator Conference. 2010 : 232-234.
  • 9Shi Jiaru, Chen Huaibi, Zheng Shuxin, et al. Comparison of measured and calculated coupling between a waveguide and an RF cavity usingCST Microwave Studio[C]//Proc of European Particle Accelerator Conference. 2006 : 1328-1330.

二级参考文献27

共引文献25

同被引文献4

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部