摘要
SL6228Φ76岩性密度测井仪是为了更好地适应钻井新技术的发展,满足当前对小井眼(小于15.5mm)测井的需求而研制的,文章通过对蓬莱某井Φ76岩性密度测井曲线自身重复,以及与常规89岩性密度测井曲线对比,研究评价Ф76小井眼岩性密度仪器稳定性及数据可信性。
The Φ76 lithology density logging instrument is developed to adapt to the new drilling technology better and meet the current needs of the logging of slim hole wells.This article researches and evaluates the stability and reliability of the Φ76 lithology density logging instrument through comparing its main logging curves to repeating curves,as well ascomparing its logging curves to those of Φ89 lithology density logging instrument.
出处
《石油仪器》
2012年第5期41-42,8-9,共2页
Petroleum Instruments