600MW四墙切圆燃烧超临界锅炉炉膛出口烟温偏差试验研究 被引量:12

Test and Study on Furnace Exit Flue Gas Temperature Deviation of 600MW Supercritical Boiler with Tangential Firing
原文传递
导出
摘要 在分析哈锅自主研发的新型墙式切圆燃烧锅炉燃烧器技术特点的基础上,针对贵溪电厂600 MW超临界锅炉炉膛出口烟温偏差过大(最大达139℃)的问题,通过调整SOFA燃烧器水平摆角、二次风及SOFA风门挡板开度,大大降低了两侧烟温偏差(降至60℃以下),提高了锅炉运行的经济性和安全性。 On the basis of analyzing the technical features of burners for wall tangential firing boiler independent designed and made by Harbin Boiler Co.Directing against the existence of big flue gas temperature deviation(up to 139℃) at the furnace exit of 600MW supercritical boiler in Guixi Power Plant,through adjusting horizontal swing angle of SOFA burners,secondary air and SOFA air damper opening,greatly reduced both sides of the flue gas temperature difference(reduced to below 60℃),improved the economy and security of the boiler operation.
出处 《电站系统工程》 北大核心 2012年第6期32-34,共3页 Power System Engineering
关键词 超临界锅炉 四墙切圆燃烧 烟温偏差 残余旋转 supercritical boiler four walls tangential firing flue gas temperature deviation residual rotation