摘要
This paper combines the advantages of both common-view time transfer and one-way timing and proposes a new one-way timing method.Owing to the limitations in users capacity and real-time,common-view time transfer can not provide time service simultaneously for mass users.A zero baseline experiment is carried out to validate its feasibility.Experimental results indicate this new method can achieve a timing accuracy within 5 ns.Users with requirements of rigorous time can employ this method to keep time synchronized with timing labs.
This paper combines the advantages of both common-view time transfer and one-way timing and proposes a new one-way timing method.Owing to the limitations in users capacity and real-time,common-view time transfer can not provide time service simultaneously for mass users.A zero baseline experiment is carried out to validate its feasibility.Experimental results indicate this new method can achieve a timing accuracy within 5 ns.Users with requirements of rigorous time can employ this method to keep time synchronized with timing labs.
基金
supported by the National Natural Science Foundation of China (Grant No. 11033004)
the Astronomy Joint Fund of Chinese Academy of Sciences (Grant No. 10778715)