期刊文献+

暗视下瞳孔直径测量方法及其评价 被引量:3

Scotopic pupil diameter measurement
原文传递
导出
摘要 随着屈光手术的不断发展,暗视下瞳孔直径的测量越来越重要。本文介绍和比较暗视下瞳孔直径的三种测量手段:传统瞳孔直径测量工具、眼前节检测仪中内置的瞳孔测量功能和运用红外技术的瞳孔测量方法。传统瞳孔直径测量工具价格低廉,操作简单,但在暗视下应用有诸多不足;眼前节检测仪中内置的瞳TLN量功能,在测量的准确性和可重复性方面,介于传统测量方法和先进的红外技术测量方法之间,是国内的主流方法;运用红外技术的瞳孔测量方法最可靠,在国外科研和临床上应用广泛,但因价格昂贵等原因,国内应用较少。(国际跟科纵览,2012,36:314—317) With the continuous development of refractive surgeries, measurement of scotopic pupil diameter becomes increasingly important. This article aims to introduce three methods of scotopic pupil diam- eter measurement: the traditional pupil diameter t tools, pupil measurement functions built in the anterior segment detectors, and infrared method. The traditional pupil diameter t tools are inex- pensive and simple to operate, but there are many deficiencies in scotopic situation. Pupil measurement functions built in the anterior segment detectors are domestic mainstream methods, the accuracy and repeat- ability of that are between the traditional method and infrared method. Infrared measurement is the most reli- able and widely used in foreign research and clinic, but seldom used in the domestic because of its high price. ( Int Rev Ophthalmol, 2012, 36: 314-317)
作者 刘雪 杨亚波
出处 《国际眼科纵览》 2012年第5期314-317,共4页 International Review of Ophthalmology
关键词 近视 外科学 角膜屈光手术 瞳孔直径 暗视 myopia/surgery corneal refractive surgery pupil diameter scotopic
  • 相关文献

参考文献20

  • 1Pop M, Payette Y, Santoriello E. Comparison of the pupil card and pupillometer in measuring pupil size. Cataract Refract Surg, 2002, 28 : 283-288.
  • 2Michael MD, Colvard G. Defining mesopic and scotopic. J Cataract Refract Surg, 2003, 29: 6-7.
  • 3Netto MV, Ambrosio R, Wilson SE. Pupil size in refractive surgery candidates. J Refract Surg, 2004, 20: 337-342.
  • 4Schallhorn SC, Kaupp SE, Tanzer DJ, et al. Pupil size and quality of vision after LASIK. Ophthalmology, 2003, 110 : 1606-1614.
  • 5Schnitzler EM, Baumeister M, Kohnen T. Scotopic measurement of normal pupils: Colvard versus Video Vision Analyzer infrared pupillometer. J Cataract Refract Surg, 2000, 26 : 859-866.
  • 6Colvard M. Preoperative measurement of scotopic pupil dilation Using an office pupillometer. J Cataract Refract Surg, 1998, 24 : 1594-1597.
  • 7Yoon MK, Sehmidt G, Lietman T, et al. Inter-and intraobserver reliability of pupil diameter measurement during 24 hours using the Colvard pupillometer. J Refract Surg, 2007, 23 : 266-271.
  • 8Bradley JC, Bentley KC, Mughal AI, et al. Clinical performance of a handheld digital infrared monocular pupillometerfor measurement of the dark-adapted pupil diameter. J Cataract Refract Surg, 2010, 36 : 277-281.
  • 9Yang H, Lee M, Kim JB, et al. Burst-shot infrared digital photography to determine scotopic pupil diameter. J Cataract Refract Surg, 2006, 32:2113-2117.
  • 10Kohnen T, Terzi E, Btihren J, et al. Comparison of a digital and a handheld infrared pupillometer for determining scotopic pupil diameter. J Cataract Refract Surg, 2003, 29 : 112-117.

二级参考文献4