期刊文献+

正荣·润城自动喷水泡沫喷淋系统设计分析 被引量:1

Design and analysis of Automatic sprinkler foam system for Zhen Rong Run Cheng Project
下载PDF
导出
摘要 随着城市建设的不断发展,越来越多的地下车库建设缓解了日益紧张的城市建设用地,但是在消防方面传统的自动喷水灭火系统已经无法满足地下车库的需求,因此本篇论文介绍了一种抗溶性水成膜泡沫喷淋系统的设计,以满足当前地下大型车库库和发电机房消防方面的需求。 With the continuous development of city construction, more and more underground park release the growing tension in the city construction land. However the traditional automatic fire sprinkler system has been unable to meet the demand of underground park. This paper introduces the design of a closed water - insoluble film - forming foam spray system in order to meet the anti fire need of current large underground park and power engine room.
作者 林勇
出处 《福建建设科技》 2012年第6期83-84,63,共3页 Fujian Construction Science & Technology
关键词 抗溶性水成膜泡沫喷淋系统 地下车库 柴油发电机房 water - insoluble film - forming foam spray system, underground ear park, diesel generator room