摘要 针对电能质量混合扰动分类问题,提出一种基于时频域多特征量的分类新方法。首先利用聚类经验模型分解方法和改进不完全S变换对扰动信号进行处理,并提取9个时频域特征值;然后,将特征量输入到分块化的自动分类系统中进行扰动识别。该方法充分考虑单一扰动之间的相互干扰,并通过互补的时频域特征量进行有效的抑制。仿真结果表明,在一定的噪声条件下,所提方法可有效分类电压暂降、电压暂升、电压短时中断、脉冲暂态、振荡暂态、谐波和闪变等电能质量扰动及其组合而成的混合扰动。 A new method for power quality mixed disturbance classification, based on time-frequency domain multiple features, was presented in the paper. Firstly, the disturbance signals were processed with ensemble empirical mode decomposition and modified incomplete S-transformation, and nine time-frequency domain characteristics were extracted. Then, the characteristies were input into the sub-block of the automatic classification system for the disturbance identification. In this method, interferences between the single disturbances were fully considered and effectively suppressed through the complementary amount of time and frequency domain features. The simulation results show that the method can effectively recognize the power quality mixed disturbances with the noise including voltage sag, voltage swell, voltage interruption, impulsive transient, oscillation transient, harmonics, flicker and their mixed ones.
作者 张杨 刘志刚
出处 《中国电机工程学报》 EI CSCD 北大核心 2012年第34期83-90,13,共8页 Proceedings of the CSEE
基金 国家自然科学基金项目(U1134205 51007074) 教育部新世纪优秀人才支持计划项目(NECT-08-0825) 中央高校基本科研业务费专项资金资助项目(SWJTU11CX141)~~
关键词 混合扰动 电能质量 改进不完全S变换 特征量 多标签分类 mixed disturbances power quality modified incomplete S-transform features multi-label classification
  • 相关文献

参考文献22

二级参考文献133

共引文献304

同被引文献300

引证文献30

二级引证文献354

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部