摘要
叙述了目前石灰石-石膏湿法烟气脱硫技术的应用现状和存在的问题,提出了基于实验室数据分析为基础的参数寻优方法,并应用该方法进行了脱硫系统的pH值和密度寻优试验,试验结果表明,优化调整后提高了系统运行的经济性和稳定性。
This paper introduces application status and existing problem in limestone-gypsum WFGD system and proposes an optimization method based on laboratory data analysis. The method is used for pH and density optimization test of desulphurization system, the result of which shows that economic efficiency and stability of the system operation are improved after the optimization.
出处
《浙江电力》
2012年第11期53-56,共4页
Zhejiang Electric Power
关键词
烟气脱硫
优化分析
调整
运行
FGD
analysis and optimization
adjustment
operation