期刊文献+

有晶状体眼后房散光型IOL植入矫正高度近视散光

Clinical study of the implantation of phakic posterior chamber Toric intraocular lens for high myopia with astigmatism
下载PDF
导出
摘要 目的:评价有晶状体眼后房散光型人工晶状体(TICL)植入术矫治高度近视散光的临床效果。方法:选自2009-10/2011-11接受TICL植入的高度近视散光患者30例50眼,术前平均屈光度球镜-10.75±2.65D,柱镜-2.85±0.75D。随访观察术后3mo~2a裸眼视力、最佳矫正视力、屈光度、内皮细胞计数等情况,分析并发症的发生情况。结果:术后裸眼视力:0.5~1.2(平均0.75±0.34)。术前最佳矫正视力:0.3~1.0(平均0.58±0.35),术后最佳矫正视力0.6~1.2(平均0.78±0.35)。达到术前矫正视力20眼(40%),超过术前最佳矫正视力30眼(60%),随访3mo~2a,视力无明显变化。术后屈光度数平均球镜-0.52±0.35D,柱镜0.52±0.25D。角膜内皮细胞计数术前3026±250个/mm2,术后3mo为3023±246个/mm2,差异无统计学意义(P<0.05)。未见严重影响视力的并发症。结论:TICL植入矫治高度近视散光安全有效,是高度近视散光患者的理想治疗方法。对眼内的长期影响需要进一步观察。 AIM: To assess the clinical outcome of the implantation of phakic posterior chamber Toric intraocular lens (TICL) for high myopia with astigmatism.METHODS:Totally 50 eyes of 30 patients with high myopia and astigmatism were treated with TICL implantation from October 2009 to November 2011. The preoperative mean spherical equivalent was -10.75±2.65D, the mean cylindrical equivalent was -2.85±0.75D. All of the patients were followed up for 3 months to 2 years. Uncorrected and best-corrected visual acuity, refraction, intraocular pressure and endothelial cell morphometry, as well as the complications were observed.RESULTS: The range of uncorrected visual acuity after operation was 0.5-1.2, mean 0.75±0.34. The range of preoperative best-corrected visual acuity was 0.3-1.0, mean 0.58±0.35. The mean best-corrected visual acuity after operation was 0.78±0.35. The uncorrected visual acuity after operation of 20 eyes was same and of 30 eyes was better than the preoperative best-corrected visual acuity. The mean spherical equivalent after operation was -0.52±0.35D, the mean cylindrical equivalent was 0.52±0.25D. Corneal endothelium counting before and after the operation had no significant difference. No serious complication was detected during the follow-up.CONCLUSION: The implantation of phakic posterior chamber TICL for high myopia with astigmatism is safe and effective. It is a suitable treatment method for high myopia.
出处 《国际眼科杂志》 CAS 2012年第12期2387-2389,共3页 International Eye Science
关键词 高度近视散光 后房散光型人工晶状体 有晶状体眼 high myopia with astigmatism posterior chamber Toric intraocular lens phakic
  • 相关文献

参考文献11

  • 1Yu A,Wang Q,Xue A. Comparison of contrast sensitivity after angle-supported,iris-fixated and posterior chamber phakic intraocular lens implantation for high myopia[J].Ophthalmologica.Journal International D'ophtalmologie.International Journal of Ophthalmology.Zeitschrift Fur Augenheilkunde,2008,(01):53-57.
  • 2Alfonso JF,Palacios A,Montes-Mico R. Myopic phakic STAAR collamer posterior chamber intraocular lenses for keratoconus[J].Journal of Refractive Surgery,2008,(09):867-874.
  • 3徐炫.可植入式接触镜治疗高度近视的临床疗效评价[J].第四军医大学学报,2008,29(10):892-892. 被引量:6
  • 4王洁,王松田,谢冰,王雪涛.有晶体眼后房型人工晶状体植入矫正高度近视的临床研究[J].中国医学创新,2011,8(1):32-33. 被引量:3
  • 5邹莺英,毕宏生,解孝锋.后房型人工晶体植入有晶体眼矫正高度近视的安全性与稳定性:11例随访[J].中国组织工程研究与临床康复,2010,14(8):1475-1478. 被引量:10
  • 6Benedetti S. Correction of myopia of 7 to 24 diopters with the artisan phakic intraocular lens:Two-year Follow-up[J].Journal of Refractive Surgery,2005,(02):116-126.
  • 7Silva RA,Jain A,Manche EE. Prospective long-term evaluation of the efficacy,safety,and Stability of the Phakic Intraocular Lens for High Myopia[J].Archives of Ophthalmology,2008,(06):775-781.doi:10.1001/archopht.126.6.775.
  • 8Kohnen T,Knorz MC,Cochener B. AcrySof phakic angle.supported intraocular lens for the correction of moderate-to-high myopia:One-year results of a multicenter European study[J].Ophthalmology,2009,(07):1314-1321.
  • 9Verde CM,Teus MA,Arranz-Marquez E. Medennium posterior chamber phakic refractive lens to correct high myopia[J].Journal of Refractive Surgery,2007,(09):900-904.
  • 10Koivula A,Taube M,Zetterstrom C. Phakic refractive lens:Two-year results[J].Journal of Refractive Surgery,2008,(05):507-515.

二级参考文献14

  • 1俞阿勇,林振德.有晶状体眼后房型人工晶状体植入术矫治中高度近视眼[J].中华眼科杂志,2005,41(6):572-576. 被引量:33
  • 2Sanders DR,Vukich JA.Comparision of implantable contact lens and laser assisted in situ keratomileusis for moderate to high myopia.Cornea,2003(22):324-331.
  • 3Sanders DR,Doney K,Poco M,et al.United States Food and Drug Administration clinical trial of the implantable collamer lens(ICL)for moderate to high myopia.Ophthalmology,2004(111):1683-1692.
  • 4Gonvers M,Othenin-Girard P,Bornet C,et al.Implantable contact lens for moderate to high myopia.J Cataract Refract Surg,2001(27):380-388.
  • 5Uusitalo RJ,Aine E,Sen NH,et al.Implantable contact lens for high myopia.J Cataract Refract Surg,2002(28):29-36.
  • 6Tsiklis NS,Kynionis GD,Karp CL,et al.Nine-year follow-up a posterior chamber phakic ICL in one eye and lasik in the fellow eye of the same patient.J Refract Surg,2007,23(9):935-937.
  • 7Feizi S,Jadidi K,Soheilian M.Possible protection of the posterior segment by a phakic intraocular lens.J Cataract Refract Surg,2007(33):2144-2146.
  • 8Loewenstein A,Goldstein M,Lazar M.Retinal pathology oceurring after excimer laser surgery or phakic intraocular lens implantation:Evaluation of possible relationship[J].Surv Ophthalmol,2002,47:125-135.
  • 9Ardjomand N,Ko” lli H,Vidie B,et al.Pupillary block after phakic anterior chamber intraocular lens implantation[J].J Cataract Refract Surg,2002,28:1080-1081.
  • 10Kawesch GM,Kezirian GM.Laser in situ keratomileusis for high myopia with the VISX Star laser[J].Ophthalmology,2000,107 (4):655-661.

共引文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部