摘要
对全分隔式、全连通式和组合连通式3种不同类型蓄热室腔道的构造特点及其优缺点进行了剖析。用实例对蓄热室腔道常规分隔做法的缺点进行了分析,提出了采用"横向分隔墙微调错位"法改进蓄热室腔道设计的具体措施。
The structural characteristics , advantages and disadvantages of 3 different type chamber of regenerator : full-separated, full-connected and hybrid type, were discussed. The disadvantage of conventional separation of regenerator chamber was analyzed by taking practical examples and the concrete measure of improving regenerator chamber design, "horizontal separation wall with fine-tune dislocation "was presented.
出处
《玻璃》
2012年第11期20-27,共8页
Glass
关键词
玻璃
熔窑
蓄热室
腔道设计
炉条砖
格子体
glass, furnace, regenerator, chamber design, fire-bar brick, checker