期刊文献+

威金斯转炉煤气柜日常运行中的故障与处理 被引量:1

Faults and Solutions in the Daily Use of Wiggins Gas Converting Cabinet
下载PDF
导出
摘要 某厂2座8万、12万m3威金斯柜在运行中出现了氧含量超标、漏气、钢丝绳断裂、柜容指示不准、活塞倾斜度测量不准等故障,通过技术改造、加强对设备的日常维护和检查、完善操作工艺等措施,取得了一定的效果,保障了气柜的可靠运行。 Some group has two Wiggins 2 gas converting cabinet of 8 000 cubic meters and 12 0000 cubic meters which have oxygen content extended, leaking problem, wire rope fracture, capacity indicating faults, and piston measurements mistakes of inclination. But through technological revolution, strengthening on daily maintenance and device checking, together with perfect operation system, effective results have been found already. It brought reliable guarantee on the machine's mouthy run in daily work.
出处 《能源研究与管理》 2012年第4期97-99,104,共4页 Energy Research and Management
关键词 威金斯柜 运行 故障 处理 Wiggins gas cabinet running problems solutions
  • 相关文献

参考文献4

  • 1武汉安全环保研究院.GB6222-2005工业企业煤气安全规程[S].北京:中国标准出版社,2005.
  • 2吕佐周.冶金燃气[M].北京:冶金工业出版社,1985:25-26.
  • 3王岭,陈红萍,王胜春.煤气基础知识[M].北京:化学工业出版社,2007.
  • 4宛定宏,朱彩霞.转炉煤气柜工程中的质量控制[J].冶金动力,2010(5):33-34. 被引量:1