摘要
采用内循环UASB对酒精废水直接进行厌氧处理,比较了连续进水与脉冲进水两种方式的处理效果,进一步验证了内循环UASB具有对COD、SS等适应范围广、污泥流失量少、对污染物去除率高等特点。试验结果表明,连续进水时冬季较其他季节处理效果差;脉冲进水时,COD、TP、SS的平均去除率分别为81%、24.02%、51.24%;由于反应器内发生了氨化反应,处理后NH3-N有不同程度的增加,需进一步好氧处理。
The inner circulating UASB has been used for treating alcohol wastewater directly by anaerobic method. The treatment efficiencies by continuous water feeding and pulse water feeding are compared. It was further verified that the inner circulating UASB is characterized by wider range of COD, SS, etc. of alcohol wastewater,less loss of sludge, and high removing rate of pollutants. The results show that the treating effect of continuous water feeding in winter is lower than any other seasons. The pulse water feeding could averagely remove 81% of COD,24.02% of TP, and 51.24% of SS, respectively. After the treatment, NH3-N has different degrees of increase because of the am- moniation reaction in the reactor. The effluent water needs further aerobic treatment.
出处
《工业水处理》
CAS
CSCD
北大核心
2012年第12期30-33,共4页
Industrial Water Treatment
基金
国家水体污染控制与治理科技重大专项(2009ZX07210-002)
关键词
酒精废水
内循环升流式厌氧污泥床
颗粒污泥
连续进水
脉冲进水
alcohol wastewater
inner circulating upflow anaerobic sludge blank
granulated sludge
continuous wa-ter feeding
pulse water feeding