期刊文献+

迭代重建技术(iDose^4)在肺部低剂量筛查中的应用 被引量:24

Application of low-dose chest CT screening with iterative reconstruction technique(iDose^4)
下载PDF
导出
摘要 目的探讨iDose4迭代重建技术在胸部低剂量筛查的方案。方法选取120例胸部体检者,根据不同的体质量指数(BMI)分为A组(BMI≤22)、B组(22<BMI<26)和C组(BMI≥26)。应用Z轴动态管电流调节技术(Z-DOM),预设A组、B组、C组管电流分别为35mAs、45mAs和60mAs,之后利用iDose4平台对各受检者图像分别进行FBP,iDose3、Dose5、iDose7重建。记录3组的CT剂量指数(CTDIvol)、剂量长度乘积(DLP),并估算有效剂量(ED)。结果所获图像质量均可满足诊断要求。A组、B组和C组的CTDIvol均值分别为(0.69±0.08)mGy、(1.09±0.17)mGy和(1.95±0.43)mGy,ED均值分别为(0.33±0.05)mSv、(0.50±0.11)mSv和(0.87±0.23)mSv。结论应用iDose4迭代重建技术,根据受检者的BMI,可获得满意的胸部低剂量CT筛查扫描方案。 Objective To assess the program of low dose chest CT screening with iterative reconstruction technique (iDose4). Methods Totally 120 subjects who underwent chest CT screening were divided into 3 groups according to body mass index (BMI) : Group A (BMI≤〈22), group B (22〈BMI〈26) and group C (BMI≥26). Z-axial dose modulation (Z- DOM) technique was used to preset tube current of group A, group B and group C as 35 mAs, 45 mAs and 60 mAs, re- spectively. Then the images were reconstructed with standard filtered back projection (FBP), iDose3, iDose5 and iDoseT, respectively. CT dose index volumes (CTDI_vol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. The imaging quality was assessed by 2 radiologists. Results The images of each group were acceptable. The average CTDI_vol for group A, B and C was (0.69±0. 08)mGy, (1.09±0.17)mGy and (1.95±0.43)mGy, respective- ly, and the average ED was (0.33±0.05)mSv, (0.50±0.11) mSv and (0.87±0.23) mSv, respectively. Conclusion Application of iDose4 iterative reconstruction technique based on BMI can achieve satisfactory scanning program of chest low-dose screening.
出处 《中国医学影像技术》 CSCD 北大核心 2012年第12期2248-2251,共4页 Chinese Journal of Medical Imaging Technology
关键词 胸部 体层摄影术 X线计算机 迭代重建 辐射剂量 Chest Tomography, X-ray computed Iterative reconstruction Radiation dosage
  • 相关文献

参考文献10

  • 1EUR 16262. European guidelines on quality criteria for computed tomography. ]-2009-07-12"]. http://ww, drs. dk/guidelines/et/ quality/download/eur16262, w51.
  • 2Lee CI, Haims AH, Monico EP, et al. Diagnostic CT scans: as- sessment of patient, physician, and radiologist awareness of radi- ation dose and possible risks. Radiology, 2004,231(2):393-398.
  • 3Berrington de Gonzalez A, Darby S. Risk of cancer from diagnos- tic X-rays: Estimates for the UK and 14 other countries. Lancet, 2004,363(9406) : 345-351.
  • 4Fujii K, Aoyama T, Koyama S, et al. Comparative evaluation of organ and effective doses for paediatric patients with those for a- dults in chest and abdominal CT examinations. Br J Radiol, 2007, 80(956) : 657-667.
  • 5Manowitz A, Sedlar M, Griffon M, et al. Use of BMI guidelines and individual dose tracking to minimize radiation exposure from low-dose helical chest CT scanning in a lung Cancer screening pro- gram. Acad Radiol, 2012,19(1) : 84-88.
  • 6陈疆红,贺文,赵丽琴,胡志海,李志欣,李娟.高清晰CT胸部低剂量筛查的临床应用[J].中国医学影像技术,2010,26(12):2302-2305. 被引量:11
  • 7陈疆红,贺文,赵丽琴,胡志海,姜荣.适应性统计迭代重建技术降低胸部低剂量CT图像噪声的效果[J].中国医学影像技术,2011,27(12):2398-2402. 被引量:35
  • 8低剂量技术进展[J].放射学实践,2011,26(10):1110-1111. 被引量:3
  • 9吴瑶媛,王万勤,刘斌,Isao Tanaka,张帅.FBP、ASiR和VEO三种重建算法对常规剂量胸部CT图像质量的影响[J].中国医学影像技术,2012,28(3):575-578. 被引量:55
  • 10Hutton B, Nuyts J, Zaidi H. Iterative reconstruction methods// [-s. n.J. Quantitative analysis in nuclear medicine imaging. Sin- gapore : Springer Science+ Business Media, ~006 : 107-140.

二级参考文献32

  • 1Lee CI,Haims AH,Monico EP,et al.Diagnostic CT scans:assessment of patient,physician,and radiologist awareness of radiation dose and possible risks.Radiology,2004,231(2):393-398.
  • 2Hall EJ,Brenner DJ.Cancer risks from diagnostic radiology.Br J Radiol,2008,81(965):362-378.
  • 3Brenner DJ,Ellison CD.Estimated radiation risks potentially associated with full-body CT screening.Radiology,2004,232(3):735-738.
  • 4Fujii K,Aoyama T,Koyama S,et al.Comparative evaluation of organ and effective doses for pediatric patients with those for adults in chest and abdominal CT examinations.Br J Radiol,2007,80(956):657-667.
  • 5Prakash P,Kalra MK,Digumarthy SR,et al.Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique:initial experience.J Comput Assist Tomogr,2010,34(1):40-45.
  • 6Kalra MK,Rizzo S,Maher MM,et al.Chest CT performed with z-axis modulation:scanning protocol and radiation dose.Radiology,2005,237(1):303-308.
  • 7Rampado O,Marchisio F,Izzo A,et al.Effective dose and image quality evaluation of an automatic CT tube current modulation system with an anthropomorphic phantom.Eur J Radiol,2009,72(1):181-187.
  • 8Prasad SR,Wittram C,Shepard JA,et al.Standard-dose and 50%-reduced-dose chest CT:comparing the effect on image quality.AJR Am J Roentgenol,2002,179(2):461-465.
  • 9Kanal KM,Stewart BK,Kolokythas O,et al.Impact of operator-selected image noise index and reconstruction slice thickness on patient radiation dose in 64-MDCT.AJR Am J Roentgenol,2007,189(1):219-225.
  • 10Prakash P, Kalra MK, Diqumarthy SR, et al. Radiation dose re- duction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. J Comput Assist Tomogr, 2010,34(1):40-45.

共引文献96

同被引文献225

  • 1张博,龚建平.CT检查辐射致癌风险的研究进展[J].国际医学放射学杂志,2009,32(3):217-220. 被引量:39
  • 2Andreas Christe,Johannes Heverhagen,Christoph Ozdoba,Christian Weisstanner,Stefan Ulzheimer,Lukas Ebner.在最后三扫描仪代的 CT 剂量和图象质量[J].World Journal of Radiology,2013,5(11):421-429. 被引量:10
  • 3范丽,刘士远,蒋涛,刘靖,钱懿.2013年度呼吸系统CT研究进展[J].肿瘤影像学,2013,22(4):343-349. 被引量:2
  • 4赵进委,沈钧康,钱农,蒋国民.MSCT冠状动脉造影的临床应用[J].中国医学影像学杂志,2005,13(1):40-45. 被引量:9
  • 5Lee CI, Haims AH, Monico EP, et al. Diagnostic CT scans: As- sessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology, 2004,231 (2):393-398.
  • 6European Study Group of Radiologist and Physicians. European guidelines on quality criteria for computed tornography. E2013-05- 01]. http://w3. tue. nl/fileadmin/sbd/Documenten/Leergang/ BSM/European Guidelines _ Quality_ Criteria _ Computed_ Tomo- graphy Eur_16252. pdf.
  • 7Hur G, Hong SW, Kim SY, et al. Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography. AJR Am J Roentgenol, 2007,189(1) : 188-196.
  • 8Herzog BA, Husmann L, Burkhard N, et al. Accuracy of low-dose computed tomography coronary angiography using prospective eleclrocardiogram-triggering: First clinical experience. Eur Heart J, 2008,29(24):3037- 3042.
  • 9Coles DR, Smail MA, Negus IS, et al. Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography. J Am Coll Cardiol, 2006,47(9) : 1840-1845.
  • 10Berrington de Gonzdlez A, Darby S. Risk of cancer from diagnostic X-rays: Estimates for the UK and 14 other countries. Lancet 200t, 363(9406):345-351.

引证文献24

二级引证文献112

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;