摘要 研究了在继电保护器中常见的电力信号谐波分析的处理方法,推导了在加窗情况下的RIFI幅值比较法的具体公式,并就电力系统这一信号特点以及继电保护器的局限性改进了这一方法,给出了具体的幅度误差分析仿真图并做出了比较。 This paper described the approach of power signal harmonic analysis in relay protection implement,derived the formula of windowed RIFI amplitude comparison.And for the signal characteristics of the power system and protection devices limitation,this approach was improved still further.The simulation image of error analysis was given and at last a comparison of the amplitudes of three spectral lines was made practically.
出处 《电子器件》 CAS 北大核心 2012年第5期562-566,共5页 Chinese Journal of Electron Devices
基金 国家自然科学基金项目(60872073 60975017 51075068) 教育部博士点专项基金项目(20110092130004)
关键词 电子测量 谐波分析 三谱线幅值比较 harmonic analysis RIFI amplitude comparison of three spectral lines
  • 相关文献

参考文献7

  • 1Rife D C, Vincent G A. Use of the Discrete Fourier Transform in the Measurement of Frequencies and Levels of Tones[ J]. Bell Sys. Tech, 1970 (49) : 197 - 228.
  • 2丁康,钟舜聪.通用的离散频谱相位差校正方法[J].电子学报,2003,31(1):142-145. 被引量:50
  • 3王力,张冰,徐伟.基于MATLAB复调制ZOOM-FFT算法的分析和实现[J].舰船电子工程,2006,26(4):119-121. 被引量:26
  • 4Peleg S, Porat B. The CRLB for Signals with Constant Amplitude and Polynomial Phase [ J ]. IEEE Trans. March 1991,46 ( 3 ) : 749 -752.
  • 5Liguori C, Paolillo A, Pignotti A. Estimation of Signal Parameters in the Frequency Domain in the Presence of Harmonic Interference : A Comparative Analysis [ J ]. IEEE Transactions on Instrumentation and Measurement ,2006,55 ( 2 ) :562-569.
  • 6Akke Magnus. Frequency Estimation by Demodulation of Two Complex Signals [ J ]. IEEE Trans on PWRD, 1997,12 ( 1 ) : 157 -163.
  • 7Reljin I, Reljin B, Papic V, et al. New Window Functions Generated by Means of Time Convolution-Spectral Leakage Error [ C ]//Electrotechnical Conference, Mediterranean, 1998:878 -881.

二级参考文献11

共引文献74

同被引文献27

  • 1吴在军,窦晓波,胡敏强.基于IEC61850标准的数字保护装置建模[J].电网技术,2005,29(21):85-88. 被引量:35
  • 2Albert H. Nuttall Some Windows with Very Good Sidelobe Behavior [ J ]. IEEE Transactions on Acoustics, Speech, and Signal Processing, 1981,29( 1 ) :84-91.
  • 3Qian Hao, Zhao Rongxiang, Chen Tong. Inter-Harmonics Analysis Based on Interpolating Windowed Fluff Algorithm [ J ]. IEEE Transactions on Power Delivery ,2007,22 (2) : 1064-1069.
  • 4Alexander A,Christoph B, Kay C. Use of IEC61850 Object Models for Power System Quality/Security Data Exchange[ J]. Quality and Security of Electric Power Delivery Systems ,2003 (10) :155-164.
  • 5Robert A. Power Quality Monitoring at the Interface between Transmission and Users [ C ]//Orlando, FL. USA : Proceedings of the 9th International Conference on Harmonics and Quality of Pow- er, 2000 : 425 -430.
  • 6IEC. Communication Networks and Systems in Substations Part 7- l:Basic Communication Structure for Substation and Feeder E- quipment-Principles and Models[ S]. 2006.
  • 7IEC. Communication Networks and Systems in Substations Part 7-4: Basic Communication Structure for Substation and Feeder Equipment Compatible Logic Node Classes and Data Classes[S]. 2003.
  • 8IEC, Communication Networks and Systems in Substations Part 6: Configuration Description Language for Communication in Electrical Substations Related to IEDs[ S]. 2004.
  • 9IEC. Communication Networks and Systems in Substations Part 5: Communication Requirements for Functions and Device Models[ S]. 2004.
  • 10Clement-Nyns K, Haesen E, Driesen J. The Impact of Charging Pug-In Hybrid Electric Vehicles on a Residential Distribution Grid[ J]. IEEE Trans on Power Systems,2010,25( 1 ) :371-380.

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部