摘要 提出了一种通过扫描滤波来提高啁啾脉冲对比度的方法,并分析了该方法的原理。与传统的非线性滤波技术不同,扫描滤波方法消除预脉冲时,选通原理是基于光的频率而不是强度。以电光双折射扫描滤波器为例,说明了扫描滤波法的具体应用。通过数值模拟及实验研究,发现电光双折射扫描滤波法可以有效地消除主脉冲以前几百ps的预脉冲,并且主脉冲同时还能保证较高的透过率。 A method using scanning filter to improve the contrast of chirped pulse is proposed, and the principle of this method is analyzed. The scanning filter is compared with the existing pulse-picking technique and nonlinear filtering technique. The scanning filter is a temporal gate that is independent on the intensity of the pulses, but on the instantaneous wavelengths of light. Taking the electro-optic birefringence scanning filter as an example, the application of scanning filter methods is illustrated. Based on numerical simulation and experimental research, it is found that the electro-optic birefringence scanning filter can elimi- nate a prepulse which is several hundred picoseconds before the main pulse, and the main pulse can maintain a high transmissivi- ty.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2013年第1期47-51,共5页 High Power Laser and Particle Beams
基金 国家自然科学基金项目(11104163) 三峡大学优秀人才科研启动基金项目(KJ2011B066)
关键词 扫描滤波 对比度 啁啾脉冲 预脉冲 电光效应 scanning filter contrast chirped pulses prepulse electro-optic effect
  • 相关文献

参考文献15

  • 1Strickland D, Mourou G A. Compression of amplified chirped optical pulses[J]. Opt Commun, 1985, 56(3):219-221.
  • 2Bahk S W, Rousseau P, Planchon T A, et al. Generation and characterization of the highest laser intensities (10zz W/cmz) [J]. Opt Lett, 2004, 29(24) :2837-2839.
  • 3Dromey B, Kar S, Zepf M. High contrast for TW-PW lasers--plasma mirrors operated in the near field[R]. High Power Laser Pro- gramme Femtosecond Pulse Physics, Central Laser Facility Annual Report. 2002/2003:76-77.
  • 4Hong K H, Hou B, Nees J A, et al. Generation and measurement of>108 intensity contrast ratio in a relativistic kHz chirped-pulse ampli- fied laser[J]. ApplPhysB, 2005, 81 (4) :447-457.
  • 5Tawney J, Richardson M, Adhav R. Electro-optic deflector isolator for short laser pulse contrast ehancement[C]//Conference on Lasers and Electro-Optics. 2001:97 98.
  • 6向世清,董景星,莽燕萍,楼祺洪,王之江.电光开关削波产生2~10ns准分子激光输出脉冲[J].中国激光,1995,22(9):675-680. 被引量:13
  • 7Jullien A, Minkovski N, Saltiel S M. 10 l0 temporal contrast for femtosecond ultraintense lasers by cross polarized wave generation[J]. Opt Lett, 2005, 30(8):920-922.
  • 8Jullien A, Albert O, Cheriaux G, et ai. Highly efficient temporal cleaner for femtosecond pulses based on cross polarized wave generation in a dual crystal scheme[J]. Appl Phys B, 2006, 84(3) : 409-414.
  • 9Mohebbi M. Nonlinear ellipse rotation of high energy femtosecond optical pulses for pulse contrast enhancement[J]. Optical and Quantum Electronics, 2004, 36 (4) : 383-387.
  • 10Shah R C, Johnson R P, Shimada T, et al. High-temporal contrast using low-gain optical parametric amplification[J]. Opt Lett, 2009, 34 (15) : 2273-2275.

二级参考文献2

  • 1Xia Z M,Opt Commun,1993年,98卷,172页
  • 2霍芸生,中国激光,1990年,17卷,增刊,7页

共引文献12

同被引文献37

  • 1江志明,徐至展.超短高功率脉冲激光与物质相互作用及其应用[J].中国激光,1996,23(6):513-519. 被引量:10
  • 2Yanovsky V, Chvykov V, Kalinchenko G, et al. Ultra-high intensity 300 TW laser at 0.1 Hz repetition rate[J]. Opt Express, 2008, 16 (3) : 2109 -2114.
  • 3L6vy A, Ceecotti T, D'Oliveira P, etal. Double plasma mirrorfor ultrahigh temporalcontrast ultraintenselaser pulses[J]. Opt Lett 2007, 32(3): 310-312.
  • 4Kiriyama H, Shimomura T, Sasao H, et al. Temporal contrast enhancement of petawatt class laser pulses[J]. Opt Lett, 2012, 37(16): 3363-3365.
  • 5Chvykov V, RousseauP, ReedS, et al. Generation of 10^11 contrast 50 TWlaser pulses[J]. OptLett, 2006, 31(10): 1456 -1458.
  • 6Dival E J, Ross I N. High dynamic range contrast measurements by use of an optical parametric amplifier correlator[J]. Opt Lett, 2004, 29 (19): 2273- 2275.
  • 7Curley P F, Darpentigny G, Cherianx G, et al. High dynamic range autocorrelation studies of a femtoseeond Ti: sapphire oscillator and its relevance to the optimization of chirped pulse amplification systems[J]. Opt Cornmun, 1995, 120(2) : 71-77.
  • 8Shah R C, Johnsona R P, Shimada T, et al. Large temporal window contrast measurement using optical parametric amplification and low- sensitivitydetectors[J]. EurPhys J D, 2009, 55: 305-309.
  • 9Dorrer C, Bromage J, Zuegel J D. High-dynamic range single-shot cross-correlator based on an optical pulse replicator[J]. Opt Express, 2008, 16(18): 13534-13544.
  • 10Zhang D, Qian L, Yuan P, et al. Fiber array based detection scheme for single shot pulse contrast characterization[J]. Opt Lett, 2008, 33 (17): 1969-1971.

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部