Energy consumption and carbon emissions of hospitals in Tianjin

Energy consumption and carbon emissions of hospitals in Tianjin
原文传递
导出
摘要 An energy audit of 22 tertiary hospitals was conducted in Tianjin. The detailed content included design data, basic information, energy bills and equipment lists. It was shown that during the study, the energy intensity of hospitals in Tianjin was approximately stable and the average level of energy consumption was 348kW.h/(m2.a). From the date collected, it was calculated that the energy intensity of general hospitals was 380 kW.h/(m2.a), and the average carbon emissions was 157kgCO2/(m2.a); While the energy intensity of specialized hospitals was 309kW'h/(m2.a), and the average carbon emissions was 131 kgCO2/(m2. a). By breaking the energy consumption down into several items, it was found that the heating system consumed the highest amount of energy (42.12%), followed by the cooling system (6.78%), the medical equipment (4.98%) and the lighting system (3.63%). The main factors that affect the hospital energy consumption were determined, and some feasible technology and management measures to save energy and reduce carbon emissions were proposed. An energy audit of 22 tertiary hospitals was conducted in Tianjin. The detailed content included design data, basic information, energy bills and equipment lists. It was shown that during the study, the energy intensity of hospitals in Tianjin was approximately stable and the average level of energy consumption was 348kW.h/(m2.a). From the date collected, it was calculated that the energy intensity of general hospitals was 380 kW.h/(m2.a), and the average carbon emissions was 157kgCO2/(m2.a); While the energy intensity of specialized hospitals was 309kW'h/(m2.a), and the average carbon emissions was 131 kgCO2/(m2. a). By breaking the energy consumption down into several items, it was found that the heating system consumed the highest amount of energy (42.12%), followed by the cooling system (6.78%), the medical equipment (4.98%) and the lighting system (3.63%). The main factors that affect the hospital energy consumption were determined, and some feasible technology and management measures to save energy and reduce carbon emissions were proposed.
出处 《Frontiers in Energy》 CSCD 2012年第4期427-435,共9页 能源前沿(英文版)
关键词 hospital building energy consumption car-bon emissions energy saving emission reduction hospital building, energy consumption, car-bon emissions, energy saving, emission reduction
  • 相关文献

参考文献1

二级参考文献5

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部