摘要
通过对高档酒店项目的系统运行特点及目前设计中存在问题的总结与分析,提出了几点节能改进措施,包括过渡季及冬季免费供冷、夏季冷凝热的利用、空调系统的管制优化以及单双盘管的优化等。从适用性、技术性、经济性等方面进一步分析了这些措施的实施产生的社会效益及经济效益,并给出了具体的设计方法。
By summarizing and analyzing the characteristics in operation and existing problems in design,proposes several energy saving improvement measures,including free cooling in winter and transition seasons,condensing heat utilization in summer,water pipe system optimization,and rational application of single and double coils.Analyses the social and economic benefit of these measures from the applicability,technical,and economic aspects,and gives some specific design methods.
出处
《暖通空调》
北大核心
2012年第12期45-49,共5页
Heating Ventilating & Air Conditioning
关键词
表冷器
冷凝热
热回收
四管制
免费供冷
生活热水
surface air cooler
condensing heat
heating recovery
four pipe system
free cooling
domestic hot water