广州地铁一号线2930车的DC/AC故障分析

DC/AC Fault Diagnosis of No.2930 Car of Line One Subway of Guangzhou
下载PDF
导出
摘要 对广州地铁一号线2930车的DC/AC所发生的严重故障,首先,通过硬件更换排除30A车DC/AC的硬件故障;然后,利用KLIP模块故障报警信号是低电平有效的原理,通过对调KLIP模块诊断反馈线路排除诊断系统的故障;再根据DC/AC内电流不平衡,推断故障为30A车DC/AC所带的两台空调压缩机负载所引起;最后,通过单独测试两台压缩机,确定故障为30B车2位端空调压缩机的电机三相不平衡而导致,从而排除2930车的DC/AC所发生的严重故障,使2930车重新得以正常运行。 In this paper the DC/AC serious failure of No.2930 car of line one subway of Guangzhou is analyzed. First of all, exclude hardware fault by exchanging hardware of the DC/AC. Secondly, exelude diagnosis system fault by replace the KLIP module feedback, At last according to the imbalance of dynarnie current we find out the boot fault cause by the imbalance of the air conditioner compressor motor which is one of the load of DC/AC for 30A car. We solve the problem and recover No. 2930 car.
作者 梁明 李兆军
出处 《装备制造技术》 2012年第12期125-127,共3页 Equipment Manufacturing Technology
基金 国家自然科学基金资助项目(51065002) 广西自然科学基金资助项目(桂科自0991055)
关键词 2930车 DC AC 故障 诊断 No. 2930 car DC/AC fault diagnosis